HW1A-B1-B IDEC, HW1A-B1-B Datasheet - Page 18

no-image

HW1A-B1-B

Manufacturer Part Number
HW1A-B1-B
Description
PUSHBUTTON SWITCH
Manufacturer
IDEC
Datasheet

Specifications of HW1A-B1-B

Actuator / Cap Color
Black
For Use With
YS Series IEC Contactors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
D
Specifications
Coil Resistance:
Operating Time:
D-18
Frame
24V 50/60Hz
48V 50/60Hz
110V 50/60Hz
120V 50/60Hz
208V 50/60Hz
220V 50/60Hz
230V 50/60Hz
240V 50/60Hz
380V 50/60Hz
415V 50/60Hz
480V 50/60Hz
500V 50/60Hz
600V 50/60Hz
12
25
38
65
125
180
300
Coil Voltage
Size
Contactor
Notes:
1.
2.
3.
4.
5.
6.
YS1N-9F
YS1N-12F
YS1N-20F
YS1N-25F
YS1N-32F
YS1N-38F
YS1N-40F
YS1N-50F
YS1N-65F
YS1N-80F
YS1N-100F
YS1N-125F
YS1N-150F
YS1N-180F
YS1N-220F
YS1N-300F
Number
Basic
Part
The operating time depends on the type of contactor electromagnet and its control mode.
The closing time is measured from the time the coil power supply is switched on to the time the main contacts first make contact.
The opening time is measured from the time the coil power supply is switched off to the time the main contacts separate.
The duration of the arcing time depends on the type of circuit switched by the poles.
For normal three-phase applications the duration of the arcing time is normally less than 10 ms.
The load is isolated from the coil power supply after a time equal to: the sum of the opening time and the arcing time.
YS1N-9F/12F YS1N-20F/25F YS1N-32F/38F YS1N-40F/50F/65F YS1N-80F/100F/125F YS1N-150F/180F YS1N-220F/300F
2577.0
2821.1
3166.4
3272.7
5136.3
174.4
196.3
619.5
748.0
776.0
841.8
7.90
33.9
11 to 17
14 to 22
15 to 23
14 to 22
10 to 27
17 to 34
17 to 36
www.idec.com
Main
Closing
11 to 17
15 to 22
15 to 23
16 to 24
10 to 26
16 to 31
16 to 36
Aux.
(NO)
1310
1480
2050
2170
3100
19.1
101
122
385
397
486
513
4.8
(msec)
8 to 12
9 to 16
8 to 16
10 to 16
6 to 19
13 to 31
13 to 33
Aux.
(NC)
50Hz
1162
1.68
36.6
44.2
134
153
153
164
458
501
675
790
7.1
Main
5 to 13
3 to 13
6 to 15
6 to 17
6 to 20
8 to 25
8 to 27
Opening
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
5 to 13
6 to 13
7 to 15
5 to 17
6 to 20
8 to 28
8 to 30
Aux.
(NO)
1046.7
137.4
139.0
162.0
177.8
426.0
562.5
757.1
794.0
Resistance ( )
39.1
45.2
1.7
6.3
(msec)
7 to 14
9 to 17
12 to 23
11 to 23
10 to 26
12 to 29
12 to 31
Aux.
(NC)
10 to 15
13 to 20
16 to 24
15 to 22
13 to 31
21 to 39
22 to 41
IEC Contactors
Main
Closing
0.39
1.85
8.67
11.6
33.3
35.6
37.2
45.6
112
133
182
191
275
10 to 15
13 to 20
16 to 24
15 to 22
12 to 30
20 to 36
21 to 38
Aux.
(NO)
(msec)
7 to 12
9 to 13
9 to 16
9 to 16
8 to 22
13 to 29
13 to 31
Aux.
(NC)
60Hz
0.298
1.182
129.2
135.2
6.46
23.2
24.8
31.4
96.6
206
7.1
30
82
5 to 13
2 to 12
5 to 14
7 to 16
6 to 18
5 to 22
5 to 24
Main
Opening
6 to 14
7 to 13
7 to 15
7 to 16
6 to 18
7 to 22
7 to 24
Aux.
(NO)
0.107
0.378
2.630
3.186
8.310
8.840
9.340
9.810
22.38
28.70
62.71
66.52
100.3
(msec)
7 to 15
9 to 17
11 to 21
11 to 20
10 to 24
11 to 29
11 to 31
Aux.
(NC)

Related parts for HW1A-B1-B