44-712 EAO, 44-712 Datasheet - Page 55

Switch Actuator

44-712

Manufacturer Part Number
44-712
Description
Switch Actuator
Manufacturer
EAO
Datasheet

Specifications of 44-712

Mounting Hole Dia
22.3mm
Mounting Type
Front Mount
For Use With
44 Series Emergency Stop Pushbutton Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Application guidelines
When switching inductive loads such as relays, DC motors, and DC solenoids, it is always important
to absorb surges (e.g. with a diode) to protect the contacts. When these inductive loads are switched
off, a counter emf can severely damage switch contacts and greatly shorten lifetime.
Fig. 1 shows an inductive load with a free-wheeling diode connected in parallel. This free-wheeling
diode provides a path for the inductor current to flow when the current is interrupted by the switch.
Without this free-wheeling diode, the voltage across the coil will be limited only by dielectric break-
down voltages of the circuit or parasitic elements of the coil. This voltage can be kilovolts in amplitude
even when nominal circuit voltages are low (e.g. 12 VDC) see Fig. 2.
The free-wheeling diode should be chosen so that the reverse breakdown voltage is greater than the
voltage driving the inductive load. The DC blocking voltage (VR) of the free-wheeling diode can be
found in the datasheet of a diode. The forward current should be equal or greater than the maximum
current flowing through the load.
To get an efficient protection, the free-wheeling diode must be connected as close as possible
to the inductive load!
0
VDC
Suppressor circuits
+
_
Switching with inductive load
Free-wheeling
Fig. 1
Switch
diode
Inductive
load
over load without free-wheeling diode
Sveral hundred
thousend volts
to several
Counter emf
0
Fig. 2
ON
OFF
e = L
__
dt
di
03.2009