PM1205 Clare, PM1205 Datasheet - Page 4

SSR, PCB MOUNT, 240VAC, 1.4V, 500mA

PM1205

Manufacturer Part Number
PM1205
Description
SSR, PCB MOUNT, 240VAC, 1.4V, 500mA
Manufacturer
Clare
Datasheets

Specifications of PM1205

Control Voltage Type
DC
Input Voltage
0.9V To 1.4V
Contact Configuration
SPST-NO
Load Current
500mA
Load Voltage Range
20Vrms To 240Vrms
Switching Mode
AC Switch
Relay Terminals
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM1205
Quantity:
62
Part Number:
PM1205
Quantity:
5 510
Part Number:
PM1205
Manufacturer:
VISHAY
Quantity:
5 510
Part Number:
PM1205C
Manufacturer:
TI
Quantity:
530
Manufacturing Information
Moisture Sensitivity
the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled
according to the limitations and information in that standard as well as to any limitations set forth in the information or
standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
ESD Sensitivity
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Board Wash
Clare recommends the use of no-clean flux formulations. However, board washing to remove flux residue is
acceptable. Since Clare employs the use of silicone coating as an optical waveguide in many of its optically isolated
products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes.
Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy
should not be used.
4
Pb
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. Clare classified all
of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry
standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
2002/95/EC
RoHS
e
3
PM1205
PM1205
Device
Device
www.clare.com
Moisture Sensitivity Level (MSL) Rating
Maximum Temperature x Time
250ºC for 30 seconds
MSL 1
PM1205
R08