8952130000 Weidmuller, 8952130000 Datasheet - Page 101

SSR, DIN RAIL, 520VAC, 30VDC/30VAC, 20A

8952130000

Manufacturer Part Number
8952130000
Description
SSR, DIN RAIL, 520VAC, 30VDC/30VAC, 20A
Manufacturer
Weidmuller
Datasheet

Specifications of 8952130000

Control Voltage Type
DC
Control Voltage Range
8VDC To 30VDC / 10VAC To 30VAC
Operating Voltage Range
24VAC To 520VAC
Peak Surge Current
250A
Load Current
20A
Switching Mode
Zero Cross
Rohs Compliant
No
Technical data
Ordering data
Accessories
MiniConditioner MCZ O
• Universal interface between control and
• Direct switching of load currents up to 2 A DC
• Tension clamp connection system
• Plug-in cross-connection
• Width 6mm
Control side
Rated voltage
Power rating
max. input frequency
Nominal auxiliary voltage
Status indicator
Load side
Nominal switching voltage
Nominal switching current
Voltage drop at max. load
Switch-on delay/Switch-off delay
Short-circuit-proof/Protective circuit
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN 50 178)
Standards
Rated voltage
Rated impulse withstand voltage
Clearance and creepage distances for control side - load side
Surge category
Pollution severity
Dimensions
Clamping range (rating- / min. / max.)
Length x width x height
Note
Connection system
Note
Note
sensor/actuator
;CE;
mVA
mn;20 %
z
/ DC: 40 ms
Tension clamp connection
mm
mm
2
24 V UC
Control side
24 V DC ±20 %
230 mW / 280 mVA
AC: 5 Hz / DC: 10 Hz
no
LED green
Load side
5…48 V DC
20 mA
≤ 1 V
AC: 10 ms / DC: 20 ms /AC: 45 ms / DC: 40 ms
no /Integrated free-wheel diode
General data
-25 °C…+50 °C
-40 °C…+85 °C
CSA;cURus;CE;
Insulation coordination (EN 50 178)
EN 50178
300 V
6.0 kV
≥ 5.5 mm
III
2
Tension clamp connection
1.5 / 0.5 / 1.5
91 x 6 x 64
Type
MCZ O 24VUC
End plate AP MCZ 1.5: 8389030000
for cross-connectors and markers - refer to MCZ Series accessories
5
llution severity
e category
inal auxiliary voltage
e drop at max. load
+
voltage
impulse withstand voltage
l switching current
4
OUTPUT
48 V = / 20 mA
d creepage distances for control side - load side
icator
ching voltage
ure (operational)
ure
3
ircuit
Qty.
10
Input
0 V
Order No.
8365940000
2
24 V
1
24 V UC / 24 V 2 A
Control side
24 V DC ±20 %
195 mW / 220 mVA
AC: 10 Hz / DC: 30 Hz
no
LED *
Load side
24 V DC ±20%
2 A
/
yes /varistor
General data
-25 °C…+40 °C
-40 °C…+60 °C
CSA;cURus;CE;
Insulation coordination (EN 50 178)
EN 50178
300 V
6.0 kV
≥ 5.5 mm
III
2
Tension clamp connection
1.5 / 0.5 / 1.5
91 x 6 x 64
* Status indicator: green = OK,
yellow = partial short circuit, blinking red = short circuit
Type
MCZ O 24VUC
End plate AP MCZ 1.5: 8389030000
for cross-connectors and markers - refer to MCZ Series accessories
Voltage drop at max. load
OUT
C: 10 ms / DC: 20 ms /AC: 45 ms / DC: 40 ms
llution severity
5
e category
inal auxiliary voltage
nal switching current
+24 V
VCC
voltage
impulse withstand voltage
indicator
d creepage distances for control side - load side
4
OUTPUT
proof/Protective circuit
2 A
ltage
ure (operational)
ure
GND
3
Optos - MCZ-SERIES
Qty.
10
0 V
Input
Order No.
8287730000
2
C.101
24V
C

Related parts for 8952130000