H3AM-NS-C300 Omron, H3AM-NS-C300 Datasheet - Page 2

TIMER, ON-DELAY, 100/240VAC, 12H

H3AM-NS-C300

Manufacturer Part Number
H3AM-NS-C300
Description
TIMER, ON-DELAY, 100/240VAC, 12H
Manufacturer
Omron
Datasheet

Specifications of H3AM-NS-C300

Contact Configuration
SPCO
Nom Input Voltage
240VAC
Delay Time Range
0.2s To 12h
Adjustment Type
Knob
Relay Mounting
Panel
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
240V
H3AM
Specifications
Note: Instantaneous output is obtained by turning the time setting knob below “0” until the time setting knob stops.
2
Operating mode
Screw tightening torque
Input type
Output type
Mounting method
Approved standards
H3AM-jjj-A
H3AM-jjj-B
H3AM-jjj-C
Rated supply voltage
Operating voltage range
Power reset (-NS)
Reset input time (-NSR)
Reset voltage range (-NSR)
Power consumption
Control output
Ambient temperature
Ambient humidity
General
Time Ranges
Ratings
Model
ode
3
6
12
Full scale on
u sca e o
di l
dial
ON-delay
0.98 N m (10 kgf) max.
Voltage input
Relay: DPDT
Flush/Panel mounting, no restriction on mounting angle.
UL 508, CSA C22.2 No. 14
Conforms to EN61812-1 (VDE0435/P2021), IEC60664-1 (VDE01104 kV/2, VDE0106/P100)
Conforms to EN50081-2 and EN50082-2
100 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Minimum power-opening time: 0.5 s
Minimum input time:
H level:
L level:
Approx. 9 VA (Approx. 5 W)
Contact output: 5 A at 250 VAC, resistive load (cos = 1)
Operating: –10 C to 55 C (with no icing)
Storage:
Operating: 35% to 85%
---
---
0.2 to12 s
s
85 to 264 VAC
0 to 10 VAC
–25 C to 65 C (with no icing)
0.5 to 30 s
1 to 60 s
2 to 120 s
10 s
0.5 s
0.05 to 3 min
0.1 to 6 min
0.2 to 12 min
min
Set time unit
0.5 to 30 min
1 to 60 min
2 to 120 min
10 min
0.05 to 3 h
0.1 to 6 h
0.2 to 12 h
h (hour)
0.5 to 30 h
1 to 60 h
---
10 h (hour)
H3AM