H3CR-A8 24-48VAC/12-48VDC Omron, H3CR-A8 24-48VAC/12-48VDC Datasheet - Page 36

TIMER, ON-DELAY

H3CR-A8 24-48VAC/12-48VDC

Manufacturer Part Number
H3CR-A8 24-48VAC/12-48VDC
Description
TIMER, ON-DELAY
Manufacturer
Omron

Specifications of H3CR-A8 24-48VAC/12-48VDC

Contact Configuration
DPCO
Nom Input Voltage
48V
Delay Time Range
0.05s To 300h
Adjustment Type
Knob
Relay Mounting
Panel
Svhc
Hexabromocyclododecane (HBCDD) And All Major Diastereoisomers Identified
Timing Adjustment
Knob
H3CR-H
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
38
Rated supply voltage (see note 1)
Operating voltage range
No-voltage input (see note 2)
Power consumption
Control outputs
Accuracy of operating
time
Setting error
Operation start voltage
Influence of voltage
Influence of
temperature
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Case color
Enclosure ratings
Weight
Ratings
Characteristics
2. For contact input, use contacts which can adequately switch 0.1 mA at 5 V.
±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)
±5% FS ±50 ms max.
30 % max. of rated voltage
±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)
±1% FS max. (±1% FS ±10 ms max. in ranges of 0.6 and 1.2 s)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying
metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;
1 kV for 24 VAC/DC, 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120
VAC, 200 to 240 VAC, 100 to 125 VDC;
1.5 kV for 24 VAC/DC, 48 VDC
±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise
simulator (pulse width: 100 ns/1 ms, 1-ns rise);
±1 kV (between power terminals) for 48 VDC
Malfunction: 8 kV
Destruction: 15 kV
Destruction:10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 98 m/s
Operating:–10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Operating: 35% to 85%
Mechanical:10 million operations min. (under no load at 1,200 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3:10 V/m (900±5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
Immunity Burst:
Immunity Surge:
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
Approx. 120 g
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)
100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz), 24 VAC/VDC (50/60 Hz), 48 VDC,
100 to 125 VDC
85% to 110% of rated supply voltage
ON-impedance:
ON residual voltage: 1 V max.
OFF impedance:
100 to 120 VAC:
200 to 240 VAC:
24 VAC/DC:
48 VDC:
100 to 125 VDC:
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
2
2
three times each in six directions
three times each in six directions
approx. 0.23 VA (0.22 W) at 120 VAC
approx. 0.35 VA (0.3 W) at 240 VAC
approx. 0.17 VA (0.15 W) at 24 VAC
approx. 0.1 W at 24 VDC
approx. 0.18 W at 48 VDC
approx. 0.5 W at 125 VDC
EN61812-1
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
1 kΩ max.
500 kΩ min.
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
IEC61000-4-3:10 V/m (80 MHz to 1 GHz)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line
2 kV line to ground (level 3)
(level 3)
H3CR-H

Related parts for H3CR-A8 24-48VAC/12-48VDC