NC4D JP 12VDC PANASONIC EW, NC4D JP 12VDC Datasheet

RELAY, PCB, 4PCO, 12VDC

NC4D JP 12VDC

Manufacturer Part Number
NC4D JP 12VDC
Description
RELAY, PCB, 4PCO, 12VDC
Manufacturer
PANASONIC EW
Datasheet

Specifications of NC4D JP 12VDC

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Coil Resistance
200ohm
Coil Type
DC Coil, Monostable
Nom Operating Power
720mW
Relay Mounting
PC
Contact Configuration
4PCO
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATIONS
Contacts
Coil (Polarized) (at 25°C 77°F)
#1 This value can change due to the switching frequency, environmental conditions,
en_ds_61135_0000: 310105J
Types
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Rating
(resistive
load)
Expected life
(minimum)
Contact material
Minimum
operating power
Nominal
operating power
Minimum set and
reset power
Nominal set and
reset power
and desired reliability level, therefore it is recommended to check this with the
actual load.
4C Vertical type (PC board)
.161
4.1
1.094
27.8
1.500
38.1
4C Flat type
1.500
38.1
Max. switching
power
Max. switching
voltage
Max. switching
current
Max. switching
carrying current
Min. switching
capacity
2 C single side stable Approx. 200 mW 500 mW
4 C single side stable Approx. 400 mW 500 mW
2 C single side stable Approx. 360 mW 900 mW
4 C single side stable Approx. 720 mW 900 mW
2 C 2 coil latching
4 C 2 coil latching
2 C 2 coil latching
4 C 2 coil latching
#1
2C
4C
11.2
.441
25.4
1.000
10.9
.429
2C: 1,250 VA 150 W
4C: 1,000 VA 150 W
5 A 250 V AC
4 A 250 V AC
5 A 30 V DC
5 A 30 V DC
Standard
5×10
5×10
10
10
2C Vertical type (PC board)
Gold-clad silver nickel
5
5
HIGH POWER BIFURCATED
2 Form C, 4 Form C
.161
5
5
at
at
4.1
1.094
at
at
27.8
Up to 48 V DC
100 µA 1 V DC
1.000
25.4
FLAT/VERTICAL TYPE
250 V AC
1.000
Approx. 1,600 mW
2C Flat type
50 mΩ
25.4
Approx. 450 mW
Approx. 900 mW
Approx. 800 mW
5 A
5 A
2C: 750 VA 150 W
4C: 500 VA 150 W
Amber sealed
3 A 250 V AC
2 A 250 V AC
5 A 30 V DC
5 A 30 V DC
5×10
5×10
CONTACT
10
10
25.4
1.000
5
5
110 V DC
11.2
.441
at
5
at
5
mm
10.9
.429
at
at
inch
FEATURES
• Space saver — Flat series and vertical series
• High contact reliability due to bifurcated contacts
• Latching types available
• Low operating power
• Soldering flux inflow prevented by terminal location
• Amber sealed types available
• High breakdown voltage for transient protection
Characteristics (at 25°C
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
Max. operating speed
Initial insulation resistance
Initial
breakdown
voltage*
Operate time (at nominal voltage)
Release time (at nominal voltage)
Operate time (latching) (at nominal voltage)
Reset time (latching) (at nominal voltage)
Temperature rise (at nominal voltage)
Shock resistance
Vibration
resistance
Conditions for operation,
transport and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
1
2
3
4
5
— 2C: 5 A 250 V AC, 4C: 5 A 125 V AC, 4 A 250 V AC
— 2C: 200 mW, 4C: 400 mW (Single side stable)
— 1,000 Vrms between open contacts, contact sets
Detection current: 10 mA
Half-wave pulse of sine wave: 11ms; detection time: 10µs
Half-wave pulse of sine wave: 6ms
Detection time: 10µs
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (see catalog).
1
Between open contacts,
contact sets
Between contacts and coil
5
NC RELAYS
Functional*
Destructive*
Functional*
Destructive
(Single
side
stable)
(2 coil latching)
Humidity
77°F
2 C
4 C
2
4
50% Relative humidity)
3
DC: –40°C to +55°C
AC: –40°C to +40°C
DC: Max. 20 ms, AC: Max. 30 ms
DC: Max. 10 ms, AC: Max. 40 ms
–40°C to +55°C
up to 48 V DC: –40°C to +70°C
110 V DC:
up to 48 V AC: –40°C to +60°C
100 V AC:
117.6 m/s
at double amplitude of 1 mm
at double amplitude of 2 mm
58.8 m/s
Min. 100 MΩ at 500 V DC
2C/Approx. 16 g
4C/Approx. 18 g
Min. 980 m/s
Min. 98 m/s
5 to 85% R.H.
1,000 Vrms
2,000 Vrms
Max. 20 ms
Max. 20 ms
2
Max. 65°C
2
180 cpm
{6 G}, 10 to 55 Hz
{12 G}, 10 to 55 Hz
–40°C to +55°C
–40°F to +158°F
–40°F to +131°F
–40°F to +140°F
–40°F to +104°F
–40°C to +40°C
–40°F to +131°F
–40°F to +104°F
–40°F to +131°F
2
2
{10 G}
{100 G}
.56 oz
.63 oz
NC
VDE
1

Related parts for NC4D JP 12VDC

NC4D JP 12VDC Summary of contents

Page 1

... High contact reliability due to bifurcated contacts 10.9 — 2C 250 V AC, 4C 125 V AC 250 V AC .429 • Latching types available • Low operating power — 2C: 200 mW, 4C: 400 mW (Single side stable) 2C Flat type • Soldering flux inflow prevented by terminal location 11.2 • ...

Page 2

... NC TYPICAL APPLICATIONS Use NC Relays for power control — Tape recorders, temperature controls, video tape recorders Telecommunications equipment, measuring controls, copiers ORDERING INFORMATION Ex. NC Contact arrangement Type classification 2: 2 Form C Nil: Standard type 4: 4 Form C EB: Amber sealed type (Notes) 1. Flat series are available in PC board terminal types only. ...

Page 3

... NC4D-JPL2-DC110V NC4D-L2-DC110V Notes: 1. Two coil latching relay 4C series are for intermittent operation only. Power should be applied to coil continuously for no more than two minutes. 2. Coil resistance is the measured value at a coil temperature of 20°C. Compensate coil resistance by plus or minus 0.4% for each degree (°C) of coil temperature change ...

Page 4

NC 4C single side stable (NC4D-JP) Standard type 5.08 5.08 5.08 5.08 5.08 5.08 .200 .200 .200 .200 .200 .200 (NC4EBD-JP) 38.1 1.500 5.08 7.62 5.08 7.62 .200 .300 .200 .300 4C 2 coil latching (NC4D-JPL2) Standard type 5.08 5.08 ...

Page 5

Standard type (NC2EBD-P) 25.4 1.000 5.08 5.08 5.08 .200 .200 .200 7.62 5.08 5.08 .300 .200 2.54 .100 4C single side stable (NC4D-P) Standard type (NC4EBD-P) 38.1 ...

Page 6

NC Slim series Plug-in series 2C single side stable Standard type (NC2D) (NC2EBD) 25.4 1.000 5.08 5.08 5.08 .200 .200 .200 7.62 5.08 7.62 .300 .200 .300 2C 2 coil latching ...

Page 7

... Same operation as conventional magnetic relays. Contacts will transfer only when coil is energized under indicated polarity coil latching Contacts will transfer only when coil is energized under indicated polarity. Once transferred, contacts remain in that position even with power off until opposite coil is energized at indicated polarity Reset set Diagrams show the “ ...

Page 8

NC 3. Operate time for single side stable Max. Max. 6 Min. 4 Min 100 110 Coil applied voltage,%V 5. Rate of change of pick-up and drop-out voltage ...

Page 9

... Flat series 250 V AC Slim series 250 V AC Initial breakdown voltage 2,000 V AC (Except for coil-coil of L2 types: 1,500 V AC) Initial insulation resistance Heat resistance Caution: Do not insert or remove relays while in the energized condition. en_ds_61135_0000: 310105J NC4 Flat NC2 Slim screws necessary. Relays are held firmly in the socket by clips integrally molded into the socket ...

Page 10

NC DIMENSIONS Flat series NC2-JPS Terminal width: 0.9 Terminal thickness: 0.4 NC2-JPL2S 2-3.5 DIA. HOLES 2-.138 DIA. HOLES 10.16 .400 25.4 1.000 Terminals 3 and 6 excluded for NC2-JPS. NC4-JPS Terminal width: 0.9 Terminal thickness: 0.4 NC4-JPL2S 2-3.5 DIA. HOLES ...

Page 11

... Reset coil 4 3 Set switch Reset switch 2. 2 coil latching series 4C are for intermittent operation only. Power should be applied to coils continuously for no more than two minutes. 3. When designing printed circuit board patterns, note that: (1) “Top View” wiring diagram is indicated for the Flat series because terminals can be seen from above ...

Related keywords