XTMC9A10TD EATON CUTLER HAMMER, XTMC9A10TD Datasheet - Page 229

CONTACTOR SPST-NO, 24VDC, 8.8A, DIN RAIL

XTMC9A10TD

Manufacturer Part Number
XTMC9A10TD
Description
CONTACTOR SPST-NO, 24VDC, 8.8A, DIN RAIL
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTMC9A10TD

No. Of Poles
3
Contact Configuration
SPST-NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Relay Terminals
Screw Clamp
Nom Operating Power
4kW
Contact Voltage Ac Nom
690V
Operating Voltage
690VAC
Switching Power Ac1
1.5hp
Switching Power Ac3
5hp
Switching Current Ac1
20A
Switching Current Ac3
8.8A
Load Current Inductive
8.8A
Load Current Resistive
20A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Catalog Number Selection (Open Components)
Table 34-269. IT. Electro-Mechanical Catalog Numbering System
Note: When using the Catalog Numbering System for Eaton’s Cutler-Hammer IT. Electro-Mechanical products, care should be exercised to
assure that the Catalog Number for the Overload Relay aligns with the IT. Contact Block selected for type, frame size and ampacity, if purchased
as separate components. Example: Select an E05N_XR_3A IT. Overload Relay for an IEC non-reversing application or an E06N_XR_3A for an IEC
reversing application.
Examples:
CA08102001E
E02NCXCXNN — FVNR Coil Controller, 54 mm
E04NB18X3N — Contact Block, 45 mm, 18 Amps
E05NCXRL3A — Solid-State Non-reversing Overload Relay, 16 – 50 Amps
E101B32J3A — FVNR B-Frame Starter, 32 Amps, with Solid-State Overload, 10 – 32 Amps
E111F25X3N — FVNR F-Frame Contactor, 250 Amps
E501D10K3A — FVR D-Frame Starter, 100 Amps, with Solid-State Overload, 14 – 45 Amps
E511B18X3N — FVR B-Frame Contactor, 18 Amps
02N = FVNR Coil Controller
03N = FVR Coil Controller
04N = Contact Block
05N = Solid-State Non-reversing Overload Relay
06N = Solid-State Reversing Overload Relay
101 = FVNR Starter
111 = FVNR Contactor
501 = FVR Starter
511 = FVR Contactor
Configuration (Open Type)
A = 27 mm
B = 45 mm
C = 54 mm
D = 76 mm
E = 105 mm
F = 140 mm
Frame Size
E = IEC
Standard
(A)
06 = 6 Amps.
09 = 9 Amps.
12 = 12 Amps.
(B)
18 = 18 Amps.
25 = 25 Amps.
32 = 32 Amps.
(C)
40 = 40 Amps.
50 = 50 Amps.
(D)
65 = 65 Amps.
85 = 85 Amps.
10 = 100 Amps.
Designator (IEC)
E 101 A 12 A 3 A
(E)
12 = 125 Amps.
16 = 160 Amps.
20 = 200 Amps.
(F)
25 = 250 Amps.
31 = 315 Amps.
42 = 420 Amps.
XC = Coil Controller
XR = Overload
For more information visit: www.eaton.com
IEC Contactors & Starters
IT. Electro-Mechanical
Catalog Number Selection
(27 mm)
A = .25 – .8
B = .59 – 1.9
C = 1.4 – 4.4
D = 2.8 – 9.0
E = 3.8 – 12
(45 mm)
A = .25 – .8
B = .59 – 1.9
C = 1.4 – 4.4
D = 2.8 – 9.0
G = 6.3 – 20
J = 10 – 32
(54 mm)
A = .25 – .8
B = .59 – 1.9
C = 1.4 – 4.4
D = 2.8 – 9.0
F = 5.0 – 16
H = 8.4 – 27
L = 16 – 50
Overload Amperes Adjustment
3 = 3-Pole
Pole Selection
A = Standard
N = Contactor or Not Applicable
(3-phase, 45 mm – 105 mm; 1- or 3-phase, 27 mm)
(76 mm)
F = 5.0 – 16
H = 8.4 – 27
K = 14 – 45
N = 31 – 100
(105 mm)
K = 14 – 45
M = 28 – 90
P = 42 – 135
R = 63 – 200
(140 mm)
P = 42 – 135
S = 84 – 270
T = 131 – 420
X = Contact Block, Coil
Controller, Contactor or
Not Applicable