LC2D12F7 SQUARE D, LC2D12F7 Datasheet

no-image

LC2D12F7

Manufacturer Part Number
LC2D12F7
Description
Contactor
Manufacturer
SQUARE D
Datasheet

Specifications of LC2D12F7

No. Of Poles
3
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
110V
Contact Voltage Ac Max
600V
Nom Operating Power
7.5kW
Contact Voltage Ac Nom
690V
Contact Current Ac Max
25A
Contact Current Max
12A
Coil Type
AC
Operating Voltage
600VAC
Switching Power Ac1
2hp
Switching Power Ac3
10hp
Switching Current Ac1
25A
Switching Current Ac3
12A
Load Current Inductive
12A
Load Current Resistive
25A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Product data sheet
Characteristics
Mar 30, 2012
LC2D12F7
TeSys D reversing contactor - 3P(3 NO) - AC-3
- <= 440 V 12 A - 110 V AC coil
Main
Range of product
Product or component
type
Device short name
Contactor application
Utilisation category
Device presentation
Poles description
Power pole contact
composition
[Ue] rated operational
voltage
[Ie] rated operational
current
Motor power kW
Motor power HP (UL /
CSA)
Control circuit type
Control circuit voltage
Auxiliary contact com-
position
[Uimp] rated impulse
withstand voltage
Overvoltage category
[Ith] conventional free
air thermal current
Irms rated making ca-
pacity
Rated breaking capac-
ity
[Icw] rated short-time
withstand current
TeSys D
Reversing contactor
LC2D
Motor control
Resistive load
AC-1
AC-3
Preassembled with reversing power busbar
3P
3 NO
<= 690 V DC for power circuit
<= 690 V AC 25...400 Hz for power circuit
12 A (<= 60 °C) at <= 440 V AC AC-3 for power cir-
cuit
25 A (<= 60 °C) at <= 440 V AC AC-1 for power cir-
cuit
7.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
5.5 kW at 415...440 V AC 50/60 Hz
5.5 kW at 380...400 V AC 50/60 Hz
3 kW at 220...230 V AC 50/60 Hz
10 hp at 575/600 V AC 50/60 Hz for 3 phases mo-
tors
7.5 hp at 460/480 V AC 50/60 Hz for 3 phases mo-
tors
3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
1 hp at 115 V AC 50/60 Hz for 1 phase motors
AC 50/60 Hz
110 V AC 50/60 Hz
1 NO + 1 NC
6 kV conforming to IEC 60947
III
25 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
250 A DC for signalling circuit conforming to IEC
60947-5-1
140 A AC for signalling circuit conforming to IEC
60947-5-1
250 A at 440 V for power circuit conforming to IEC
60947
250 A at 440 V for power circuit conforming to IEC
60947
140 A 100 ms signalling circuit
120 A 500 ms signalling circuit
100 A 1 s signalling circuit
210 A <= 40 °C 1 s power circuit
105 A <= 40 °C 10 s power circuit
61 A <= 40 °C 1 min power circuit
30 A <= 40 °C 10 min power circuit
1

Related parts for LC2D12F7

LC2D12F7 Summary of contents

Page 1

... Product data sheet Characteristics Mar 30, 2012 LC2D12F7 TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 110 V AC coil Main Range of product TeSys D Product or component Reversing contactor type Device short name LC2D Contactor application Motor control Resistive load Utilisation category AC-1 AC-3 Device presentation ...

Page 2

Associated fuse rating <= 690 V coordination type 2 for power circuit <= 690 V coordination type 1 for power circuit for signalling circuit conforming to IEC 60947-5-1 ...

Page 3

Complementary Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Auxiliary contacts type Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance Environment IP degree of protection Protective ...

Related keywords