XTCE012B10TD EATON CUTLER HAMMER, XTCE012B10TD Datasheet - Page 75

CONTACTOR, SPST-NO, 24VDC, 12A, DIN RAIL

XTCE012B10TD

Manufacturer Part Number
XTCE012B10TD
Description
CONTACTOR, SPST-NO, 24VDC, 12A, DIN RAIL
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTCE012B10TD

No. Of Poles
3
Contact Configuration
SPST-NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Relay Terminals
Screw Clamp
Nom Operating Power
6.5kW
Contact Voltage Ac Nom
690V
Operating Voltage
690VAC
Switching Power Ac1
2hp
Switching Power Ac3
10hp
Switching Current Ac1
22A
Switching Current Ac3
12A
Load Current Inductive
12A
Load Current Resistive
22A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Table 34-115. Coil Data — Frame L – R (Continued)
Voltage Tolerance
Power Consumption of the coil at cold state and 1.0 x U c
Switching Time at 100% Main Contact U c (approximate values)
Reaction in Threshold and Sealing State Transition Range (XTCE185L – XTCEC20R)
CA08102001E
Description
Pick-Up (x U c )
Drop-Out (x U c )
XTCE185L – XTCEC20R
XTCS185L -– XTCS500M
Duty Factor (%DF)
XTCE185L – XTCEC20R
XTCS185L – XTCS500M
Voltage interruptions
Permissible contact resistance (of the external
command device with actuation of A11), Ω
Permissible residual current (with actuation of
A11 by the electronics with 0 signal)
SPS Signal Level (A3 – A4) to
IEC/EN 61131-2 (Type 2)
Electromagnetic compatibility (EMC)
Voltage Dips
Excess Voltage
Pick – Up phase
XTCE185L – XTCEC20R
XTCS185L – XTCS500M
XTCE185L – XTCEC20R
XTCS185L – XTCS500M
Pick-Up VA
Pick-Up W
Sealing VA
Sealing W
Pick-Up VA
Pick-Up W
Sealing VA
Sealing W
Closing delay (mS)
Opening delay (mS)
Closing delay (mS)
Opening delay (mS)
High
Low
(0 – 0.2 x U cmin ) ≤ 10ms
(0 – 0.2 x U cmin ) > 10ms
(0.2 – 0.6 x U cmin ) ≤ 12ms
(0.2 – 0.6 x U cmin ) > 12ms
(0.6 – 0.7 x U cmin )
(0 – 0.7 x U cmin )
(0.7 x U cmin –1.15 x U cmax )
Control transformer with U k ≤7%.
(1.15 – 1.3 x U cmax )
(>1.3 x U cmax ) ≤ 3s
(>1.3 x U cmax ) > 3s
(>1.15 x U cmax )
XTCE580N
800
700
7.5
6.5
100
<70
<70
≤500
≤1
15V
5V
This product is designed for operation in industrial environments. Usage in domestic areas can cause radio
frequency interference (RFI). Noise suppression measures must be provided for the additional interference.
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters
XTCE750N, XTCE820N
800
700
7.5
6.5
100
<70
<70
≤500
≤1
15V
5V
Contactor switches on with certainty
Contactor switches on with certainty
Contactor remains switched on
Contactor remains switched on
Contactor remains switched on
Contactor does not switch on
0.7 x U cmin — 1.15 x U cmax
0.85 x U cmin — 1.1 x U cmax
Time is bridged successfully
Time is bridged successfully
0.2 x U cmin — 0.6 x U cmax
0.2 x U cmin — 0.4 x U cmax
Drop-out of the contactor
Drop-out of the contactor
Drop-out of the contactor
XTCEC10N
800
700
7.5
6.5
100
<70
<70
≤500
≤1
15V
5V
XTCEC14P
800
700
7.5
6.5
100
<70
<40
≤500
≤1
15V
5V
XTCE16R, XTCEC20R
1600
1400
15
13
100
<70
<40
≤500
≤1
15V
5V
34-75
34

Related parts for XTCE012B10TD