STA333W STMicroelectronics, STA333W Datasheet - Page 19

no-image

STA333W

Manufacturer Part Number
STA333W
Description
DIG AUDIO SYSTEM, 2-CH, 36POWERSSOP
Manufacturer
STMicroelectronics
Datasheet

Specifications of STA333W

Svhc
No SVHC (15-Dec-2010)
Package / Case
PowerSSO
Interface
I2S
No. Of Pins
36
Operating Temperature Range
0°C To +70°C
Supply Voltage Max
18V
Supply Voltage Min
4.5V
Termination T
RoHS Compliant
Interface Type
I2S
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STA333W
Manufacturer:
st
Quantity:
2 300
Part Number:
STA333W
Manufacturer:
ST
0
Part Number:
STA333W
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA333W 2*20W
Manufacturer:
ST
0
Part Number:
STA333W######
Manufacturer:
ST
0
Part Number:
STA333W.
Manufacturer:
ST
0
Part Number:
STA333W13T
Manufacturer:
ST
0
Part Number:
STA333W13TR
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
STA333W13TR
Quantity:
7 000
STA333W
5.3
5.3.1
5.3.2
5.4
5.4.1
5.4.2
5.4.3
Write operation
Following the START condition the master sends a device select code with the RW bit set
to 0. The STA333W acknowledges this and then waits for the byte of internal address. After
receiving the internal byte address the STA333W again responds with an
acknowledgement.
Byte write
In the byte write mode the master sends one data byte, this is acknowledged by the
STA333W. The master then terminates the transfer by generating a STOP condition.
Multi-byte write
The multi-byte write modes can start from any internal address. The master generating a
STOP condition terminates the transfer.
Figure 9.
Read operation
Current address byte read
Following the START condition the master sends a device select code with the RW bit set
to 1. The STA333W acknowledges this and then responds by sending one byte of data. The
master then terminates the transfer by generating a STOP condition.
Current address multi-byte read
The multi-byte read modes can start from any internal address. Sequential data bytes are
read from sequential addresses within the STA333W. The master acknowledges each data
byte read and then generates a STOP condition terminating the transfer.
Random address byte read
Following the START condition the master sends a device select code with the RW bit set
to 0. The STA333W acknowledges this and then the master writes the internal address byte.
After receiving, the internal byte address the STA333W again responds with an
acknowledgement. The master then initiates another START condition and sends the device
select code with the RW bit set to 1. The STA333W acknowledges this and then responds
by sending one byte of data. The master then terminates the transfer by generating a STOP
condition.
MULTIBYTE
WRITE
WRITE
BYTE
START
START
Write-mode sequence
DEV-ADDR
DEV-ADDR
RW
RW
ACK
ACK
Doc ID 13365 Rev 2
SUB-ADDR
SUB-ADDR
ACK
ACK
DATA IN
DATA IN
ACK
ACK
STOP
I
2
C bus specification
DATA IN
ACK
19/49
STOP