A3992SB-T Allegro Microsystems Inc, A3992SB-T Datasheet - Page 8

no-image

A3992SB-T

Manufacturer Part Number
A3992SB-T
Description
IC, MOTOR DRIVER FULL BRIDGE 1.5A DIP-24
Manufacturer
Allegro Microsystems Inc
Datasheet

Specifications of A3992SB-T

Motor Type
Full Bridge
No. Of Outputs
4
Output Current
1.5A
Output Voltage
50V
Supply Voltage Range
4.5V To 5.5V
Driver Case Style
DIP
No. Of Pins
24
Applications
Stepper Motor Driver
Number Of Outputs
1
Current - Output
±1.5A
Voltage - Load
15 V ~ 50 V
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-20°C ~ 85°C
Mounting Type
Through Hole
Package / Case
24-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
620-1169-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A3992SB-T
Manufacturer:
ALLEGRO
Quantity:
8 636
A3992
Charge Pump (CP1 and CP2).
used to generate a gate supply greater than V
drive the source FET gates. A 0.22 μF ceramic capaci-
tor is required between CP1 and CP2 for pumping
purposes. A 0.22 μF ceramic capacitor is required
between VCP and the VBB terminals to act as a reser-
voir to operate the high-side FETs.
Sleep Mode.
to minimize power consumption when not the device
is not in use. This disables much of the internal circuit-
ry including the output DMOS, regulator, and charge
pump. Logic low puts the device into Sleep mode,
logic high allows normal operation and startup of the
device into the home position. When asserted low,
the serial port is reset. All bits are reset to 0s, with the
exception of D7, the fi xed off-time MSB, which is set
to 1. This prevents the off-time from being too short,
which could result in a loss of current control. When
coming out of Sleep mode, allow 1 ms before issuing
a step command, to allow the charge pump to stabilize.
Shutdown.
junction temperature, or to low voltage on V
V
fault condition is removed. At power up, and in the
event of low V
ers and resets the data in the serial port.
REG
, the outputs of the device are disabled until the
In the event of a fault due to excessive
Control input on the SLEEP pin is used
DD
(A) Short-to-ground event
, the UVLO circuit disables the driv-
2 A / div.
500 ns / div.
Fault latched
The charge pump is
CP
BBx
or
to
Microstepping PWM Motor Driver
Short to Ground.
ground, the current through the short will rise until the
overcurrent (OCP) threshold is exceeded, a minimum
of 2 A. The driver will turn off after a short propaga-
tion delay and latch the device. The device will remain
latched until the SLEEP input goes high or VDD
power is removed. As shown in panel A of the fi gure
below, a short to ground will produce a single overcur-
rent event.
Shorted Load.
rent path is through the sense resistor. The device will
be protected, however, the device does not see this as a
fault because the current path is not interrupted, so this
condition will not latch the part.
When a bridge turns on, the current will rise and ex-
ceed the overcurrent threshold. After a blank time of
approximately 1μs, the driver will look at the voltage
on the SENSE pin. The voltage on the SENSE pin will
be larger than the voltage set by the VREF pin, and
the bridge will turn off for the time set by the OSC
pin. Panel B of the fi gure below shows a shorted load
condition with an off-time of 30 μs.
MUX.
use and has no function to the end user. In the applica-
tion, this pin can be tied to ground or left fl oating.
The MUX pin is reserved for Allegro internal
DMOS Dual Full-Bridge
(B) Short-to-load event
During a shorted load event, the cur-
Should a motor winding short to
2 A / div.
5 μs / div.
t
off
115 Northeast Cutoff, Box 15036
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 (508) 853-
5000
www.allegromicro.com
= 30 μs
8