102.1947 FISCHER CONNECTORS, 102.1947 Datasheet - Page 38

SEALING CAP, MATING FACE OF RECEPTACLE

102.1947

Manufacturer Part Number
102.1947
Description
SEALING CAP, MATING FACE OF RECEPTACLE
Manufacturer
FISCHER CONNECTORS
Datasheet

Specifications of 102.1947

Accessory Type
Sealing Cap
Rohs Compliant
Yes
For Use With
Mating Face Of The Receptacles
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G
Fischer Connectors SA manufactures connectors in several body styles and sizes which are specifically designed for
thermocouple applications. Most of these are also available in environmentally sealed versions, with either the «A» or «Z»
contact polarity.
The selection of the correct thermocouple contact materials is important in minimizing measurement errors. We can supply
the following contact types suitable for thermocouple applications:
G
G
For connectors with cable clamps, two versions are available:
G
G
Version «M»
This version of the 102 series is designed to accept semi-rigid cables in stainless steel tubes (Thermocoax®). To facilitate
assembly, the contact block of these connectors has a metal sleeve to which the thermocouple tubing is soldered. The cable
entry diameter «D» should be added to the reference number, which can be selected from the table on page G2. Available
body styles are shown in section A. Cable entries are available in increments of 0.5 mm from 0.6 to 3.1 mm diameter.
Example: Panel mounted cable receptacle, 2 pole; NiCr - Ni, PTFE insulator, for 1.5 mm diameter semi-rigid cable.
Note:
Version «P»
This version of the 102 series thermocouple connectors is furnished with a one-piece clamp which is designed to secure the
flexible cables typically used for compensation or extension. It may also be used for Thermocoax ® cables with crimp
ferrule termination.
To order, the reference number of the thermocouple can be selected from the table on page G2 and the body style prefix
from section A.
For cable connectors, the part numbers of the cable clamp sets should be added as a second line item. These cable clamp
sets are listed in the tables «U» on pages H1 - H5.
Example: Straight plug, 2 pole, Fe - CuNi, PTFE insulator, for flexible cable with outer diameter of 4.5 mm:
In all versions, the longer contact termination is the electrically positive material.
Contacts made of different thermocouple materials
Gold-plated copper alloy contacts
«M» version for semi-rigid cables in stainless steel tubes (Thermocoax®)
«P» version for flexible compensation and extension cables
for THERMOCOAX ®
Version «M»
D = Cable diameter max. 3.1 mm
Part Number is DK 102 A005-M / 1.5
Standard Thermocoax® cables up to 1 mm diameter are now delivered with a 3 mm diameter crimp ferrule
with reinforced wires, providing easier assembly. This type of Thermocoax® requires the use of the version
«P» connectors.
Part Number of the plug: « S 102 A009 » and for the cable clamp: « E3 102.5 / 4.5 »
Contact block of version «M»
for semi-rigid cables
+
CONNECTORS FOR THERMOCOUPLES
102 Series
Contact block and cable clamp of version «P» for compensation
cables and THERMOCOAX® ≤ 1 mm diameter
Version «P»
1
D = Cable clamp sets are ordered
D =