NPS45-M Emerson Network Power, NPS45-M Datasheet

POWER SUP MED&ITE 24V 45W 2"X4"

NPS45-M

Manufacturer Part Number
NPS45-M
Description
POWER SUP MED&ITE 24V 45W 2"X4"
Manufacturer
Emerson Network Power
Series
NPS40-Mr
Datasheet

Specifications of NPS45-M

Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
60W
Efficiency
87%
Approvals
CB, CE, CSA, NEMKO, TUV, UL
Line Regulation
±2%
Load Regulation
±2%
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
60W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 2.5A
Size / Dimension
4" L x 2" W x 1" H (101.6mm x 50.8mm x 25.4mm)
Commercial/medical
Both
Output Power Rating
40 W, 60 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 300 VDC
Output Voltage (channel 1)
24 V
Output Current (channel 1)
1.9 A
Mounting Style
Chassis
Dimensions
2 in L x 4 in W x 0.86 in H
Open Frame/enclosed
Open Frame
Output Type
DC
Output Voltage
24V
Input Frequency
47 to 440Hz
Screening Level
Commercial
Product Length (mm)
101.6mm
Product Height (mm)
25.4mm
Product Depth (mm)
50.8mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1482
NPS45-M
NPS40-M Series
60 Watts
Special Features
• Medical and ITE Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
• International Efficiency Level V,
• Less than 300 mW no-load
• 0˚C to +80˚C operation
• Input power < 74 watts
• Complies with EN61000 -3-2
• UL Class I approved
• LPX50 enclosure kit available
Safety
Total Power:
Input Voltage:
# of Outputs:
protection
(CISPR 22 Class B)
Energy Star 2.0 & CeC compliant
(except NPS42-M)
power consumption
TUV: 60950, 60601-1
UL:
CSA: 60950, 60601-1
NEMKO: 60950, 60601-1
CB:
CE:
60950, 60601-1
Mark (LVD)
Certificate and report
45 - 60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input power:
Efficiency:
EMI/RFI:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 30-50% above nominal output
Remote sense:
90 - 264 VAC (wide range) 127-300 Vdc
47-440 Hz
< 50 A peak @ 230 VAC, cold start @ 25° C
< 74 Watts
87% average (as per Energy Star 2.0 standard)
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B
conducted, VDE0878PT3 Class B conducted
275uA @ 50/60 Hz; 264 VAC input
45W for convection (40W for NPS42-M). 60 W with 200LFM forced air
(55 Watts for NPS42-M)
±20% minimum
10/ 2 0 ms 115/230 VAC input line
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Compensated for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 9.15.09_163
NPS40-M Series
1 of 3

Related parts for NPS45-M

NPS45-M Summary of contents

Page 1

NPS40-M Series 60 Watts Total Power Watts Input Voltage 264 VAC 127 - 300 VDC # of Outputs: Single Special Features • Medical and ITE Safety Approvals • Universal input • Less than 1U high • 2” x 4” footprint • Remote sense • Overload and short circuit protection • Adjustable output voltage • High efficiency • High MTBF • Built in EMI filter (CISPR 22 Class B) • International Efficiency Level V, Energy Star 2.0 & CeC compliant (except NPS42-M) • Less than 300 mW no-load power consumption • 0˚C to +80˚C operation • Input power < 74 watts • Complies with EN61000 ...

Page 2

Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -45 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing BARCODE M1 GND TAB (CN1) PIN 1 PIN 3 INPUT CONNECTOR (SK1) 0.16” (4.0) MOUNTING HOLE (4 PLACES) 0.197” (5.0) MINIMUM STANDOFF HEIGHT 4.00" (101.6) 3.73" ...

Page 3

... Regulation Load 1 Cooling Forced Air 3. 5 4.4 A 1.9 A 2.5 A 2.75 A 0.94 A 1.25 A 1.38 A NPS44-M NPS45-M Line Line Neutral Neutral +15 V +24 V +15 V +24 V Common Common Common Common -Sense -Sense +Sense +Sense Embedded Power for Business-Critical Continuity Americas 5810 Van Allen Way Ripple P/P ...