LPT101-M Emerson Network Power, LPT101-M Datasheet - Page 2

PWR SUP MED TRI 3.3V,5V,12V 130W

LPT101-M

Manufacturer Part Number
LPT101-M
Description
PWR SUP MED TRI 3.3V,5V,12V 130W
Manufacturer
Emerson Network Power
Series
LPT100-Mr
Datasheet

Specifications of LPT101-M

Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
130W
Efficiency
82%
Approvals
AUSTEL, CB, CE, CSA, NEMKO, TUV, UL
Line Regulation
±2%, ±5%
Load Regulation
±2%, ±5%
Voltage - Output
3.3V, 5V, 12V
Number Of Outputs
3
Power (watts)
130W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 18A
2nd Output
5 VDC @ 9A
3rd Output
12 VDC @ 2.3A
Size / Dimension
4" L x 2" W x 1.28" H (102mm x 51mm x 32.6mm)
Output Power Rating
66 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 300 VDC
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
20 A
Output Voltage (channel 2)
5 V
Output Current (channel 2)
10 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
2.3 A
Mounting Style
Chassis
Power Supply Output Type
Variable
No. Of Outputs
3
Input Frequency
63Hz
Output Voltage
3.3V
Output Current
18A
Power Rating
130W
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1479
LPT101-M
Environmental Specifications
Mechanical Drawing
Operating temperature:
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
MTBF calculated:
PIN 3 (NEUTRAL)
PIN 1 (LIVE)
SK1
GND
0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C start up
-40 °C to +85 °C
designed to meet EN61000-4;
-2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95%
IEC68-2-6 to the levels of IEC721-3-2
583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore
Output Voltage
Adjust Pots
Output Voltage
Adjust Pots
SK3
Mounting Hole
ø
Max. Screw Head
Diameter .22” (5.6)
0.16” [4.0] 4 Places
0.197” (5.0) Minimum
SK2
Standoff height
Embedded Power for
Business-Critical Continuity
Rev. 01.14.11_141
LPT100-M Series
2 of 3

Related parts for LPT101-M