MC13892VL Freescale Semiconductor, MC13892VL Datasheet - Page 95

no-image

MC13892VL

Manufacturer Part Number
MC13892VL
Description
IC PMU I.MX51/37/35/27 186MAPBGA
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MC13892VL

Applications
Battery Management, Display (LED Drivers), Handheld/Mobile Devices, Power Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
186-LFBGA
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Mounting
Surface Mount
Package Type
BGA
Case Length
12mm
Screening Level
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Voltage - Supply
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC13892VL
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC13892VL
Manufacturer:
FREESCALE/PBF
Quantity:
9 633
Part Number:
MC13892VLR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
CHARGER OPERATION
USB CHARGING
drive capability.
appropriate charge current level ICHRG[2:0] = (0001) is 80 mA typical which accounts for the additional current through the
charge LED indicator.
WALL CHARGING
pin must be forced low as a charger attach indicator. The CHRGSE1B pin has a built-in weak pull-up to VCORE. In the
application, this pin is preferably pulled low, with for instance an NPN of which the base is pulled high through a resistor to
CHRGRAW. The state of the CHRGSE1B pin is reflected through the CHRGSE1BS bit. When CHRGSE1B changes state a
CHRGSE1BI is generated. No specific debounce is applied to the CHRGSE1B detector.
CHRGRAW on the PCB. For these applications, charging from USB is no longer possible. For proper operation, a 120 kOhm
pull-down resistor should be placed at VBUS.
STANDALONE CHARGING
battery to be revived without processor control. This is especially important when charging from a USB host or when in single
path configuration (M3 replaced by short, BATTFET floating). Since the default voltage and current setting of the charge path
regulator may not be the optimum choice for a given application, these values can be reprogrammed through the SPI if the
CHGAUTOVIB bit is set. Note that the power limiter can be programmed independent of this bit being set.
charge current level (80 mA). When the battery voltage rises above the BATTON = 3.4 V threshold, a power up sequence is
automatically initiated. The lowest charge current level remains selected until a higher charge current level is set through the SPI
after negotiation with the USB host. In case of a power up failure, a second power up will not be initiated to avoid an ambulance
mode, the charger circuitry will though continue to charge. The USB dead battery operation following the low power boot scheme
is described further in this chapter.
configurations.
internal trickle charge current source will be enabled, set to its lowest level (40 mA) up to BATTMIN, followed by the highest
setting (80 mA). The internal trickle charge current is not programmable, but can be turned off by the SPI. In this mode, the
voltage and current regulation to BP through the external pass devices M1M2 can be reprogrammed through the SPI. Once the
battery is greater than BATTON, it will be connected to BP and further charged through M1/M2 at the same time as the
application.
will be detected and the external charge path will be used to precharge the battery, up to BATTMIN at the lowest level (80 mA),
and above at the 500 mA minimum level. Once exceeding BPON, a turn on event is generated and the voltage and current levels
can be reprogrammed.
will not be powered up, and the same charging scheme is followed as for single path.
Analog Integrated Circuit Device Data
Freescale Semiconductor
The USB VBUS line in this case, is used to provide a supply within the USB voltage limits and with at least 500 mA of current
When trickle charging from the USB cable, it is important not to exceed the 100 mA, in case of a legacy USB bus. The
No distinction can be made between a USB Host or a wall charger. Therefore, when attaching a wall charger, the CHRGSE1B
If an application is to support wall chargers and USB on separate connectors, it is advised to separate the VBUS and the
A standalone charge mode of operation is provided to minimize software interaction. It also allows for a completely discharged
Upon connecting a USB host to the application with a dead battery, the trickle cycle is started and the current set to the lowest
Upon connecting a charger to an application with a dead battery the behavior will be different for serial path and single path
In serial path (M3 present), the application will be powered up with the current through M1M2 set to 500 mA minimum. The
In single path (M3 replaced by a short, BATTFET floating), the battery (and therefore BP) is below the BPON threshold. This
When in the serial path and upon initialization of the charger circuitry, and it appears BP stays below BPON, the application
Table 76. Charger Detector Characteristics
CHRGSE1B Pull Up
Logic Low
Logic High
Parameter
To VCORE
Condition
Min
1.0
0
-
Typ
100
-
-
BATTERY INTERFACE AND CONTROL
VCORE
Max
0.3
FUNCTIONAL DEVICE OPERATION
-
kOhm
Units
V
V
13892
95

Related parts for MC13892VL