PC28F00AP33TFA NUMONYX, PC28F00AP33TFA Datasheet - Page 73

no-image

PC28F00AP33TFA

Manufacturer Part Number
PC28F00AP33TFA
Description
IC FLASH 1GBIT P33 65NM 64EZBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of PC28F00AP33TFA

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
1G (64M x 16)
Speed
95ns
Interface
Parallel
Voltage - Supply
2.3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
904253
904253
PC28F00AP33TF 904253

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PC28F00AP33TFA
Manufacturer:
Micron Technology Inc
Quantity:
10 000
P33-65nm
Figure 31: Program Suspend/Resume Flowchart
Datasheet
75
Yes
Read Status Register
Read Status Register
Write Confirm D0h
Another Buffered
Issue Write to Buffer
Is WSM Ready ?
Write Word Count
Write Buffer Data
Program Complete
Command E8h
Block Address
Check if Desired
Programming?
Supports Buffer
Target Address
Block Address
Block Address
Set Timeout or
Block Address
Loop Counter
Start Address
Full Status
X = N?
Get Next
SR. 7 =?
(note 7)
Writes ?
SR. 7 =
Device
X = 0
Start
1
1 = Yes
Yes
Yes
No
No
No
Write Buffer Data
Abort Bufferred
Buffered Program
Use Single Word
Block Address
Write to another
Block Address
Programming
Program?
Timeout
or Count
Expired ?
No
X = X + 1
Aborted
Suspend
Program
No
Yes
No
Yes
Yes
Suspend
Program
Loop
Notes:
1. Word count values on DQ
register. Count ranges for this device are N=0000h to 01FFh.
2. The device outputs the Status Register when read.
3. Write Buffer contents will be programmed at the device start
address or destination flash address .
4. Align the start address on a Write Buffer boundary for
maximum programming performance (i.e., A
address =0).
5. The device aborts the Buffered Program command if the
current address is outside the original block address .
6. The Status register indicates an “improper command
Sequence” if the Buffered Program command is aborted.
Follow this with a Clear Status Register command .
7. The device defaults to output SR data after the Buffered
Programming Setup Command (E8h) is issued . CE# or OE#
must be be toggled to update Status Register . Don’t issue the
Read SR command (70h), which would be interpreted by the
internal state machine as Buffer Word Count.
8. Full status check can be done after all erase and write
sequences complete . Write FFh after the last operation to
reset the device to read array mode.
( Notes 1, 2)
( Notes 3, 4)
( Notes 5, 6)
Operation
Standby
Standby
(Note 7)
Read
Write
Write
Write
Write
Write
Bus
Read
Command
Confirm
Program
Write to
Buffer
.
0
-DQ
SR. 7 = Valid
Addr = Address within buffer range
Status register Data
CE # and OE# low updates SR
1 = Device WSM is Busy
0 = Device WSM is Ready
1 = WSM Ready
0 = WSM Busy
N = 0 corresponds to count = 1
Data = E8H
Addr = Block Address
Addr = Block Address
Check SR .7
Data = N- 1 = Word Count
Addr = Block Address
Data = Write Buffer Data
Data = Write Buffer Data
Addr = Block Address
Data = D0H
Addr = Block Address
Addr = Block Address
Check SR .7
15
are loaded into the Count
Comments
.
9
-A
1
of the start
Order Number:208043-05
.
Apr 2010

Related parts for PC28F00AP33TFA