TLF14CBH4730R2K1 Taiyo Yuden, TLF14CBH4730R2K1 Datasheet - Page 9

no-image

TLF14CBH4730R2K1

Manufacturer Part Number
TLF14CBH4730R2K1
Description
CHOKE COMMON MODE 47000UH
Manufacturer
Taiyo Yuden
Series
TLF14CBHr
Datasheet

Specifications of TLF14CBH4730R2K1

Current
200mA
Inductance
47mH
Dc Resistance (dcr)
3.6 Ohm Max
Filter Type
Common Mode - 2 Line Array
Package / Case
0.906" L x 0.867" W x 0.690" H (23.00mm x 22.00mm x 17.50mm)
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Impedance
-
Other names
587-2829
le0104fi01_reli-RP5
【Test Method and Remarks】
【Test Method and Remarks】
【Test Method and Remarks】
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
LA Type
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
FB : Solvent temperature : 20~25℃
LA Type
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
LA, CA
LHL□□□・FB : Accoding to JIS C0025
FL
LA Type
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
LA, CA : Temperature : 40±2℃
FB : Temperature : 60±2℃
22. Resisitance to solvent
23. Thermal shock
24. Damp heat
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
RELIABILITY DATA
Duration
Solvent type
Recovery
Humidity
Duration
Recovery
Humidity
Duration
Recovery
: Conditions for 1cycle
: Accoding to JIS C0025
Number of cycles : 5 cycles
Recovery
Conditions for 1 cycle
Number of cycles : 10 cycles 〔LHL□□□〕
Recovery
Conditions for 1 cycle
Number of cycles : 10 cycles
Recovery
: 90~95%RH
: 1000 hrs
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
Step
Step
Step
1
2
3
4
1
2
3
4
1
2
3
4
: 90~95%RH
: 1000 hrs
: At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
: 30±5 sec.
: Acetone, trichloroethylene
: 3hrs of recovery under the standard condition after the test.
Minimum operating temperature
Room temperature
Minimum operating temperature
Room temperature
Room temperature
Room temperature
Temperature (℃)
ー25
+85
: At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs.
: 5 cycles (FBA, FBR)
: 4 to 24hrs of recovery under the standard condition after the removal from the test chamber. 〔LHL□□□〕
: 3hrs of recovery under the standard condition after the removal from the test chamber. (FBA, FBR)
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
Room temperature
Room temperature
Temperature (℃)
Temperature (℃)
+0
ー3
+2
ー0
Please avoid the ultrasonic cleaning of this product.
No significant abnormality in appearance
△L/L : Within ±10% Q : 30min
△L/L : Within ±10%
Appearance : No abnormality
Appearance : No abnormality
Refer to individual specification
Appearance : No abnormality
△L/L : Within ±10% Q : 30min
△L/L : Within ±10%
Appearance:No abnormality
+85
ー25
+0
ー3
+2
ー0
Duration (min.)
Within 3
Within 3
30±3
30±3
+0
ー3
+2
ー0
Duration (min.)
Duration (min.)
Within 3
Within 3
Within 3
Within 3
30±3
30±3
30±3
30±3
Inductance change : Within ±10%
Impedance change : Within ±20%
Impedance change : Within ±20%
Impedance change:Within ±20%
Impedance change : Within ±20%
1 1
Q change : Within ±30% (LHLP:only △L/L)
le0104fi01_reli_e-01

Related parts for TLF14CBH4730R2K1