AUIRLR3410 International Rectifier, AUIRLR3410 Datasheet - Page 12

no-image

AUIRLR3410

Manufacturer Part Number
AUIRLR3410
Description
MOSFET N-CH 100V 17A DPAK
Manufacturer
International Rectifier
Series
HEXFET®r
Datasheet

Specifications of AUIRLR3410

Input Capacitance (ciss) @ Vds
800pF @ 25V
Fet Type
MOSFET N-Channel, Metal Oxide
Fet Feature
Logic Level Gate
Rds On (max) @ Id, Vgs
105 mOhm @ 10A, 10V
Drain To Source Voltage (vdss)
100V
Current - Continuous Drain (id) @ 25° C
17A
Vgs(th) (max) @ Id
2V @ 250µA
Gate Charge (qg) @ Vgs
34nC @ 5V
Power - Max
79W
Mounting Type
Surface Mount
Package / Case
TO-252-3, DPak (2 Leads + Tab), SC-63
Transistor Polarity
N-Channel
Resistance Drain-source Rds (on)
155 mOhms
Drain-source Breakdown Voltage
100 V
Gate-source Breakdown Voltage
16 V
Continuous Drain Current
17 A
Power Dissipation
79 W
Mounting Style
SMD/SMT
Gate Charge Qg
22.7 nC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AUIRLR3410
Manufacturer:
IR
Quantity:
12 500
Part Number:
AUIRLR3410
Manufacturer:
IR
Quantity:
20 000
Part Number:
AUIRLR3410TR
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
AUIRLR3410TR
Quantity:
10 000
Company:
Part Number:
AUIRLR3410TRL
Quantity:
4 800
Company:
Part Number:
AUIRLR3410TRL
Quantity:
4 800
AUIRLR3410
Unless specifically designated for the automotive market, International Rectifier Corporation and its subsidiaries
(IR) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to
its products and services at any time and to discontinue any product or services without notice. Part numbers
designated with the “AU” prefix follow automotive industry and / or customer specific requirements with regards
to product discontinuance and process change notification. All products are sold subject to IR’s terms and
conditions of sale supplied at the time of order acknowledgment.
IR warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with IR’s standard warranty. Testing and other quality control techniques are used to the extent IR
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
IR assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using IR components. To minimize the risks with customer products and
applications, customers should provide adequate design and operating safeguards.
Reproduction of IR information in IR data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alterations is an unfair and deceptive business practice. IR is not responsible or liable
for such altered documentation. Information of third parties may be subject to additional restrictions.
Resale of IR products or serviced with statements different from or beyond the parameters stated by IR for that
product or service voids all express and any implied warranties for the associated IR product or service and is
an unfair and deceptive business practice. IR is not responsible or liable for any such statements.
IR products are not designed, intended, or authorized for use as components in systems intended for surgical
implant into the body, or in other applications intended to support or sustain life, or in any other application in which
the failure of the IR product could create a situation where personal injury or death may occur. Should Buyer
purchase or use IR products for any such unintended or unauthorized application, Buyer shall indemnify and hold
International Rectifier and its officers, employees, subsidiaries, affiliates, and distributors harmless against all
claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any
claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges
that IR was negligent regarding the design or manufacture of the product.
IR products are neither designed nor intended for use in military/aerospace applications or environments unless
the IR products are specifically designated by IR as military-grade or “enhanced plastic.” Only products
designated by IR as military-grade meet military specifications. Buyers acknowledge and agree that any such
use of IR products which IR has not designated as military-grade is solely at the Buyer’s risk, and that they are
solely responsible for compliance with all legal and regulatory requirements in connection with such use.
IR products are neither designed nor intended for use in automotive applications or environments unless the
specific IR products are designated by IR as compliant with ISO/TS 16949 requirements and bear a part number
including the designation “AU”. Buyers acknowledge and agree that, if they use any non-designated products
in automotive applications, IR will not be responsible for any failure to meet such requirements.
For technical support, please contact IR’s Technical Assistance Center
http://www.irf.com/technical-info/
WORLD HEADQUARTERS:
233 Kansas St., El Segundo, California 90245
Tel: (310) 252-7105
12
www.irf.com

Related parts for AUIRLR3410