TCP404XL Tektronix, TCP404XL Datasheet - Page 3

no-image

TCP404XL

Manufacturer Part Number
TCP404XL
Description
Test Probes Probe, DC-2MHz 500A DC, 750A DC
Manufacturer
Tektronix
Datasheet

Specifications of TCP404XL

Color
Black
Equipment Type
Test Probe Set
Accuracy
1% of Reading (Typ.)
Application
Semiconductor devices, power inverters⁄converters, electronic ballasts, industrial⁄consumer electronics, mobile communications, motor drives and transportation system
Bandwidth
2 MHz
Current, Rating
500 A Continuous
Impedence, Insertion
0.8 Ohms @ 1 MHz
Length, Cable
315 in.
Sensitivity
1 A⁄mV @ 750 A (Peak Pulse)
Standards
UL Listed, CSA Certified
Time, Rise
175 ns (Max.)
Voltage, Rating
500 Adc
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Safety Certifications
U.S. NRTL Listing
Canadian Certification
European Union Compliance
Other
Electromagnetic Compatibility
Power Requirements
(TCPA300/TCPA400 Amplifiers)
Power Requirements (Probes)
Probe Model
Warranty
Probe Mechanical Characteristics
Probe Cable Length
Probe Jaw Size
(Max Conductor Size)
Length
Width
Height
Weight
TCPA300 and TCPA400 Mechanical Characteristics
Length
Width
Height
Weight
Environmental Characteristics
Temperature – Operating
Temperature – Nonoperating
Humidity – Operating
Humidity – Nonoperating
Altitude – Operating
Altitude – Nonoperating
*
*
1
2
Calculated from Rise Time.
Derated w/ duty cycle and frequency.
Characteristics
TCP312 w/TCPA300
continued
TCP312
CAN/CSA C22.2 No.1010.1
IEC61010-1/A2 (Amplifier)
Meets: EC Council Directive 89/336/EEC, FCC Part 15, Subpart B Class A, AS/NZS 2064.1/2
1.5 meters (60 in.)
3.8 mm (0.15 in.)
0.15 kg (0.33 lbs.)
1.6 cm (0.625 in.)
3.2 cm (1.25 in.)
20 cm (7.87 in.)
EN61010-1/A2
UL3111-1
(Amplifier)
(Amplifier)
(Amplifier)
Requires TCPA300 Amplifier
TCP305 w/TCPA300
5% to 85% R.H. +30 ºC to +50 ºC (86 ºF to 122 ºF)
5% to 85% R.H. +30 ºC to +75 ºC (86 ºF to 167 ºF)
TCP305
AC/DC Current Measurement Systems
–40 ºC to +75 ºC (–40 ºF to 167 ºF)
90 V to 264 V; 47 to 440 Hz; 50 W
5% to 95% R.H. to +30 ºC (86 ºF)
5% to 95% R.H. to +30 ºC (86 ºF)
12,192 m (40,000 ft.) maximum
0 ºC to +50 ºC (32 ºF to 122 ºF)
Maximum CAT II (Auto Switch)
2000 m (6800 ft.) maximum
1.14 kg (2.5 lbs.)
17.3 cm (6.8 in.)
16.7 cm (6.6 in.)
9.14 cm (3.6 in.)
TCPA300
1 Year
TCP303 w/TCPA300
26.8 cm (10.55 in.)
2 meters (78.7 in.)
0.66 kg (1.45 lbs.)
TCP312
15.6 cm (6.13 in.)
4.1 cm (1.60 in.)
TCP303
21 mm x 25 mm (0.83 x 1.0 in.)
EN61010-1/A2; EN61010-2-032
CAN/CSA C22.2 No.1010.2.032
TCP305
UL3111-2-032 ; UL3111-1
CAN/CSA C22.2 No.1010.1
Product Type
(Probe and Amplifier)
(Probe and Amplifier)
(Probe and Amplifier)
(Probe and Amplifier)
IEC61010-2-032
IEC61010-1/A2
EN61010-1/A2
TCP303
www.tektronix.com/accessories
TCP404XL w/TCPA400
Requires TCPA400 Amplifier
26.8 cm (10.55 in.)
0.88 kg (1.90 lbs.)
8 meters (315 in.)
15.6 cm (6.13 in.)
4.1 cm (1.60 in.)
TCPA400
TCP404XL
TCP404XL
3

Related parts for TCP404XL