TCP305 Tektronix, TCP305 Datasheet - Page 2

no-image

TCP305

Manufacturer Part Number
TCP305
Description
Test Probes DC-50MHZ 50A DC
Manufacturer
Tektronix
Datasheet

Specifications of TCP305

Bandwidth
50 MHz
Equipment Type
Current Probe Amplifier System
Accuracy
±1% of Reading (Typ.)
Application
Semiconductor devices, power inverters⁄converters, electronic ballasts, industrial⁄consumer electronics, mobile communications, motor drives and transportation system
Current, Rating
50 A Continuous
Length, Cable
60
Sensitivity
10 A⁄V @ 50 A (Peak Pulse)
Standards
UL Listed, CSA Certified
Time, Rise
7 ns (Max.)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2
AC/DC Current Measurement Systems
Measurement Errors and
Manual Calculations Are
Now a Thing of the Past
With this new series of current measurement
tools, automatic control and on-screen
scaling and units is provided for users of
Tektronix TDS3000, TDS400A, TDS500, TDS600,
TDS700, TDS5000, TDS6000 and TDS7000
series oscilloscope systems.
Bandwidth (–3 dB)
Rise Time
Maximum Current Ratings:
High Current Sensitivity Range
DC (continuous)
RMS (sinusoidal)
Peak Pulse
Low Current Sensitivity Range
DC (continuous)
RMS (sinusoidal)
Peak Pulse
DC Accuracy
(Operating temp 0 ºC to 50 ºC)
DC Accuracy, Typical
(Operating temp 23 ºC ±5 ºC)
Nominal
Maximum Bare Wire Voltage
Lowest Measurable Current
(at ±3% accuracy at DC)
Insertion Impedance
(See Curves Below)
Typical
Maximum Amp-Second Product
(Based on Amplifier
Range Setting)
AC Coupling Low
Frequency Bandwidth
Displayed RMS Noise
(at 20 MHz Bandwidth Limit)
Signal Delay
(Delay to Output BNC)
Inputs (Probe Amplifier)
Probe Open Indicator
Overload Indicator
Termination Indicator
Non-compatible Probe Indicator
TCPA300
Product Type
Characteristics
TCP312
www.tektronix.com/accessories
TCP305
TCP312 w/TCPA300
TCP303
0.15
0.27
0.7
500A*µS – 10A/V
0.08
±3% of reading
±1% of reading
50A*µS – 1A/V
DC – 100 MHz
10 A/V Range
Scope Set To 1mV/div and 20 MHz BW Limited
1 A/V Range
250 µA
21.2A
17 ns
1 mA
3.5 ns
3.5A
at 100 MHz
30A
50A
50A
5A
at 10 MHz
at 50 MHz
at 1 MHz
TCPA400
For Use With Insulated Wires Only
RMS
Status LEDs quickly show you TCP300/400
series operating status or potential error con-
ditions that may have caused measurement
errors in the past.
The TCP300 / TCP400 Current Measurement
Systems seamlessly integrate with your TDS
series oscilloscope and the TDSPWR2 software
TCP404XL
TCP305 w/TCPA300
0.035
0.12
0.4
500A*µS – 5A/V
±3% of reading
±1% of reading
DC – 50 MHz
10 A/V Range
5 A/V Range
NA – 10A/V
1.25 mA
35.4A
17.7A
19 ns
5 mA
50A
50A
25A
50A
at 50 MHz
7 ns
at 10 MHz
at 1 MHz
<7 Hz (Low Pass – 3 dB point)
RMS
YES
YES
YES
YES
1
±3% of reading (10 ºC to 50 ºC)
TCP303 w/TCPA300
+3%/–6% of reading
15,000A*µS – 50A/V
0.025
3,000A*µS – 5A/V
0.01
0.1
(0 ºC to <10 ºC)
±1% of reading
50 A/V Range
DC – 15 MHz
5 A/V Range
Scope Set To 1mV/div and 20 MHz BW Limited
2.5 mA
17.7A
53 ns
150A
150A
500A
500A
5 mA
23 ns
25A
at 15 MHz
package to easily make those time consuming
power measurements and calculations for you.
Even non-TEKPROBE systems can use the
TCPA 300/400 series to make proper current
measurements by simply multiplying the
measured output voltage on the oscilloscope
by the TCPA 300/400 series range setting.
at 1 MHz
at 5 MHz
RMS
600V RMS CAT I & II
300V RMS CAT III
TCP404XL w/TCPA400
0.6 m at 100 kHz
0.1 m at 10 kHz
16 m at 2 MHz
±3% of reading
±1% of reading
8 m at 1 MHz
500A (750A*
DC – 2 MHz*
1A/mV Range
NA – 1A/mV
250 mA
103 ns
175 ns
500A
750A
N/A
1A
RMS
2
1
)

Related parts for TCP305