TCP303 Tektronix, TCP303 Datasheet - Page 3

no-image

TCP303

Manufacturer Part Number
TCP303
Description
Test Probes DC-15MHZ 150A DC
Manufacturer
Tektronix
Datasheet

Specifications of TCP303

Bandwidth
15 MHz
Equipment Type
Current Probe Amplifier System
Accuracy
± 1% of Reading (Typ.)
Application
Semiconductor devices, power inverters⁄converters, electronic ballasts, industrial⁄consumer electronics, mobile communications, motor drives and transportation system
Current, Rating
150 A Continuous
Impedence, Insertion
90 to 264 V
Length, Cable
78.7 in.
Sensitivity
50 A⁄V @ 500 A (Peak Pulse)
Standards
UL Listed, CSA Certified
Time, Rise
23 ns (Max.)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Safety Certifications
U.S. NRTL Listing
Canadian Certification
European Union Compliance
Other
Electromagnetic Compatibility
Power Requirements
(TCPA300/TCPA400 Amplifiers)
Power Requirements (Probes)
Probe Model
Warranty
Probe Mechanical Characteristics
Probe Cable Length
Probe Jaw Size
(Max Conductor Size)
Length
Width
Height
Weight
TCPA300 and TCPA400 Mechanical Characteristics
Length
Width
Height
Weight
Environmental Characteristics
Temperature – Operating
Temperature – Nonoperating
Humidity – Operating
Humidity – Nonoperating
Altitude – Operating
Altitude – Nonoperating
*
*
1
2
Calculated from Rise Time.
Derated w/ duty cycle and frequency.
Characteristics
TCP312 w/TCPA300
continued
TCP312
CAN/CSA C22.2 No.1010.1
IEC61010-1/A2 (Amplifier)
Meets: EC Council Directive 89/336/EEC, FCC Part 15, Subpart B Class A, AS/NZS 2064.1/2
1.5 meters (60 in.)
3.8 mm (0.15 in.)
0.15 kg (0.33 lbs.)
1.6 cm (0.625 in.)
3.2 cm (1.25 in.)
20 cm (7.87 in.)
EN61010-1/A2
UL3111-1
(Amplifier)
(Amplifier)
(Amplifier)
Requires TCPA300 Amplifier
TCP305 w/TCPA300
5% to 85% R.H. +30 ºC to +50 ºC (86 ºF to 122 ºF)
5% to 85% R.H. +30 ºC to +75 ºC (86 ºF to 167 ºF)
TCP305
AC/DC Current Measurement Systems
–40 ºC to +75 ºC (–40 ºF to 167 ºF)
90 V to 264 V; 47 to 440 Hz; 50 W
5% to 95% R.H. to +30 ºC (86 ºF)
5% to 95% R.H. to +30 ºC (86 ºF)
12,192 m (40,000 ft.) maximum
0 ºC to +50 ºC (32 ºF to 122 ºF)
Maximum CAT II (Auto Switch)
2000 m (6800 ft.) maximum
1.14 kg (2.5 lbs.)
17.3 cm (6.8 in.)
16.7 cm (6.6 in.)
9.14 cm (3.6 in.)
TCPA300
1 Year
TCP303 w/TCPA300
26.8 cm (10.55 in.)
2 meters (78.7 in.)
0.66 kg (1.45 lbs.)
TCP312
15.6 cm (6.13 in.)
4.1 cm (1.60 in.)
TCP303
21 mm x 25 mm (0.83 x 1.0 in.)
EN61010-1/A2; EN61010-2-032
CAN/CSA C22.2 No.1010.2.032
TCP305
UL3111-2-032 ; UL3111-1
CAN/CSA C22.2 No.1010.1
Product Type
(Probe and Amplifier)
(Probe and Amplifier)
(Probe and Amplifier)
(Probe and Amplifier)
IEC61010-2-032
IEC61010-1/A2
EN61010-1/A2
TCP303
www.tektronix.com/accessories
TCP404XL w/TCPA400
Requires TCPA400 Amplifier
26.8 cm (10.55 in.)
0.88 kg (1.90 lbs.)
8 meters (315 in.)
15.6 cm (6.13 in.)
4.1 cm (1.60 in.)
TCPA400
TCP404XL
TCP404XL
3