H3DE-M2AC/DC24-230 Omron, H3DE-M2AC/DC24-230 Datasheet - Page 26

Stopwatches / Timers MULTI-FUN SOLID STAT

H3DE-M2AC/DC24-230

Manufacturer Part Number
H3DE-M2AC/DC24-230
Description
Stopwatches / Timers MULTI-FUN SOLID STAT
Manufacturer
Omron
Type
Multifunctionr

Specifications of H3DE-M2AC/DC24-230

Timing Range
0.1 s to 120 Hrs
Supply Voltage
25 VAC to 230 VAC, 24 VDC to 28 VDC
Accuracy
+/- 1 %
Current Rating (max)
5 A
Display Type
Hand Dial
Operating Temperature Range
- 10 C to + 55 C
Termination Style
Screw
Time Range
0.1 Sec. To 120 Hr.
Supply Voltage Max
230VDC
Time Range Max
120h
Switch Function
DPDT
Time Range Min
0.1s
Supply Voltage Min
24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
■ Characteristics
Note: For reference:
Accuracy of operating time ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Degree of protection
Weight
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 100 mA at 5 VDC (failure level: P).
±10% ± 0.05 s max. of FS
±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range)
±2% max. of FS (±2% ± 10 ms max. at 1.2-s range)
100 MΩ min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1
min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
3 kV (or 1 kV for 24/48 VAC/VDC models) (between power supply terminals)
4.5 kV (or 1.5 kV for 24/48 VAC/VDC models) (between current-carrying metal parts and exposed non-current-
carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise) ±1.5 kV (between power
supply terminals)
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 100 m/s
Destruction: 1,000 m/s
Mechanical: 10 million operations min. (under no load at 1,200 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst:
Immunity Surge:
IP30 (IP20 for terminal block)
Approx. 120 g
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)
2
2
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-3-2
EN61000-3-3
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 3)
EN61000-4-4: 2 kV power port and output port (level 3)
EN61000-4-5: 2 kV common mode (level 3)
8 kV air discharge (level 3)
1 kV control port with capacitive clamp (level 3)
1 kV differential mode (level 3)
H3DE-H