ACD-20SW Amprobe, ACD-20SW Datasheet - Page 3

Clamp Multimeters & Accessories 400A SWIVEL CLAMP

ACD-20SW

Manufacturer Part Number
ACD-20SW
Description
Clamp Multimeters & Accessories 400A SWIVEL CLAMP
Manufacturer
Amprobe
Type
Current Clampr
Datasheet

Specifications of ACD-20SW

Ranging
Auto, Manual
Accuracy
+ / - 0.5 %
Frequency
50 Hz to 500 Hz
Maximum Ac Current
40 A, 400 A
Voltage
400 mV, 4 V, 40 V, 400 V, 600 V
Features
Test leads, installed battery, user manual, carrying case included
Dmm Type
Clamp
Voltage Measuring Range Dc
400mV To 600V
Voltage Measuring Range Ac
4V To 600V
Current Measuring Range Ac
40A To 400A
No. Of Digits / Alpha
3-3/4
Battery Life
200 hours typical with carbon-zinc.400 hours typical with alkaline
Battery Type
(2) AAA
Dimensions
12" × 5.3" × 1.2"
Jaw Opening
30 mm (1.18 In.) conductor
Polarity
Automatic, positive implied, negative polarityindication
Resistance, Range
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Voltage Range
600 V
Voltage, Range, Ac
4 V, 40 V, 400 V, 600 V
Voltage, Range, Dc
400 mV, 4 V, 40 V, 400 V, 600 V
Weight
1.26 Lbs.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
3472723
ACD-20SW Swivel Clamp Meter
Resistance
Continuity
Diode Test
Non-Contact Voltage Indicator
Auxiliary Features
Disable Auto Power Off
Noise Filter
Amprobe® Test Tools
Ranges
Resolution
Accuracy
Open Circuit Volts
Overload Protection
Range
Resolution
Audible Indication
Response Time
Overload Protection
Test current
Accuracy
Resolution
Open Circuit Volts
Audibe Indication
Overload Protection
Hold
Range
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
0.1Ω
±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
-0.45V dc typical, (-1.2Vdc on 400Ω range)
600VDC or AC rms
400Ω
Less than 25Ω
500ms
600VDC or AC rms
1.2mA (appreximate)
±(3.0% rdg + 3 dgts)
10mV
3.0Vdc typical
< 0.25V
600VDC or AC rms
Sense voltage 70V to 600VAC (50Hz ~ 60Hz) beeper chirps and big bright red LED comes on, works
when meter dial is on any ranges.
Freeze the latest reading on the display.
Excute manual range mode.
Set the DMM to off position, press (RANGE) button, and hold the (RANGE) button while turning the
rotary knob to the desired range position. Release the button when LCD displays normally. Note
“APO” annunciator is missing from the LCD. The Auto Power Off mode is activated with an “APO”
symbol indicating on LCD.
stable and consistent readings in electrically noisy environments. Pass lamp dimmer test and variable
fre-quency drive test.
www.Amprobe.com
Data Sheet