ACD-20SW Amprobe, ACD-20SW Datasheet - Page 2

Clamp Multimeters & Accessories 400A SWIVEL CLAMP

ACD-20SW

Manufacturer Part Number
ACD-20SW
Description
Clamp Multimeters & Accessories 400A SWIVEL CLAMP
Manufacturer
Amprobe
Type
Current Clampr
Datasheet

Specifications of ACD-20SW

Ranging
Auto, Manual
Accuracy
+ / - 0.5 %
Frequency
50 Hz to 500 Hz
Maximum Ac Current
40 A, 400 A
Voltage
400 mV, 4 V, 40 V, 400 V, 600 V
Features
Test leads, installed battery, user manual, carrying case included
Dmm Type
Clamp
Voltage Measuring Range Dc
400mV To 600V
Voltage Measuring Range Ac
4V To 600V
Current Measuring Range Ac
40A To 400A
No. Of Digits / Alpha
3-3/4
Battery Life
200 hours typical with carbon-zinc.400 hours typical with alkaline
Battery Type
(2) AAA
Dimensions
12" × 5.3" × 1.2"
Jaw Opening
30 mm (1.18 In.) conductor
Polarity
Automatic, positive implied, negative polarityindication
Resistance, Range
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Voltage Range
600 V
Voltage, Range, Ac
4 V, 40 V, 400 V, 600 V
Voltage, Range, Dc
400 mV, 4 V, 40 V, 400 V, 600 V
Weight
1.26 Lbs.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
3472723
ACD-20SW Swivel Clamp Meter
General Specifications
Display
Polarity
Overrange
Zero
Low Battery Indication
Auto Power Off
Measurement Rate
Operating Environment
Storage Ttemperature
Accuracy
Temperature Coefficient
Altitude
Jaw Opening Capability
Power
Isolated Battery Compartment.
Battery Life
Dimensions
Weight
Safety
Electrical Specifications
DC Volts
AC Volts (50hz - 500hz)
AC Current (50hz - 60hz)
Amprobe® Test Tools
Ranges
Resolution
Accuracy
Input Impedance
Overload Protection
Ranges
Resolution
Accuracy
Input Impedance
Overload Protection
Ranges
Resolution
Accuracy
Overload Protection
3¾ digit liquid crystal display (LCD) with a maximumreading of 3999.
Automatic, positive implied, negative polarityindication.
(OL) or (-OL) is displayed.
Automatic.
The “ “ is displayed when thebattery voltage drops below the operating level.
Approx. 10 minutes.
2 times per second, nominal.
0°C to 50°C / 32°F to 122°F at <70% relativehumidity.
-20°C to 60° / -4°F to 140°F, 0 to 80% R.H. withbattery removed from meter.
Stated accuracy at 74°F ±8°F, <75% relativehumidity.
0.1 × (specified accuracy) per °F,(32°F to 66°F, 82°F to 122°F).
6561.7 Feet (2000m).
30mm (1.18 in) conductor.
1.5 volt battery x2, R03/SIZE AAA.
200 hours typical with carbon-zinc.400 hours typical with alkaline.
306 × 135 × 30mm (12 × 5.3 × 1.2 in).
Approx. 157g (1.26lb) including battery.
Designed to meet IEC 61010-1 (EN61010-1) andIEC 61010-2-032 (EN61010-2-032) , CATIII 600V class II
and pollution degree 2 indoor use comply with CE , UL
400mV, 4V, 40V, 400V, 600V
0.1mV
±(0.5% rdg + 2 dgts)
400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ
600VDC or AC rms To measure millivolts, use “RANGE “ button to manually select 400mV range.
4V, 40V, 400V, 600V
1mV
±(1.2% rdg + 5 dgts)
±(1.5% rdg + 5 dgts) on 600V range
4V:10MΩ;40V~600V:9.1MΩ
600 VDC or AC rms
40A , 400A
0.01A
±(2.0% rdg + 6 dgts) 50 ~ 60Hz
400A AC
www.Amprobe.com
Data Sheet