VPL24-1100 Triad Magnetics, VPL24-1100 Datasheet

Transformers 24V@1.04A 12V@2.08A 25VA

VPL24-1100

Manufacturer Part Number
VPL24-1100
Description
Transformers 24V@1.04A 12V@2.08A 25VA
Manufacturer
Triad Magnetics
Type
Power Transformersr
Series
Worldr
Datasheets

Specifications of VPL24-1100

Power Rating
25 VA
Product
Transformers - Miscellaneous
Brand/series
World Series™/VPL Series
Configuration
Bobbin
Current, Secondary
2.08/1.04 A
Dimensions
3.125"W×1.937"H×2.125"D
Frequency
50/60 Hz
Length, Lead
8 "
Mounting Hole Centers
2.812 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Power, Rating
25 VA
Standards
UL
Termination
Leadwires
Voltage, Primary
115/230 VAC
Voltage, Secondary
12/24 VAC
Weight
1.3 lbs.
Mounting Style
Foot
Height
1.937 in
Length
3.25 in
Termination Style
Wire Leads
Width
2.125 in
Current Rating
2.08A
Transformer Mounting
Chassis
Peak Reflow Compatible (260 C)
Yes
Transformer Type
Power
Supply Voltage
230V
Output Voltage
12V
Output Current
2.08A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
VPL24-1100
Electrical Specifications (@25C)
1. Maximum Power: 25.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz
3. Output Voltage – Series: 24.0V CT@ 1.040A
4. Voltage Regulation: 20% TYP @ full load to no load
Construction:
Dual bobbin construction with an insulated shroud, both made of a high
temperature material that exceeds UL flammability requirements. Shrouds are
provided over the connections of the leads to the windings on both primary and
secondary coils. Devices are designed with a minimum of 6mm creepage distance
between the primary and secondary.
Safety:
These units are designed with 3500VAC isolation between the primary and
secondary, and also, between each winding and the core. Since the dual bobbin
construction effectively reduces capacitance, electrostatic shielding is not required.
International Series Transformers are designed and manufactured to meet most
International Safety agency standards.
Devices are manufactured with a Class B (130º C) insulation system.
Dimensions:
1.937
Weight: 1.3 lbs.
D. Mounting Holes: x 2
Schematic:
Input:
Output: Series – RED to GRY, Jumper YEL to VIO
Primary and secondary windings are designed to be connected in series or parallel. Windings are
not intended to be used independently.
RoHS Compliance:
requirements of 2002/95/EC, known as the RoHS initiative.
A
3.250
Parallel – BLK to WHT, Jumper BLK to BRN and WHT to BLU
Parallel – RED to VIO, Jumper RED to VIO and YEL to GRY
Series – BLK to BLU, Jumper WHT to BRN
B
3.125
C
Parallel: 115VAC@ 50/60Hz
As of manufacturing date February 2005, all standard products meet the
Parallel: 12.0V @ 2.080A
2.812
D
Units: In inches
8.00
E
WHT
BRN
BLU
BLK
.187
F
RED
YEL
GRY
VIO
P
Chassis Mount : International Series
O W E R
T
R A N S F O R M E R
F
A
B
D
C
E

Related parts for VPL24-1100

VPL24-1100 Summary of contents

Page 1

... VPL24-1100 Electrical Specifications (@25C) 1. Maximum Power: 25.0VA 2. Input Voltage – Series: 230VAC @ 50/60Hz Parallel: 115VAC@ 50/60Hz 3. Output Voltage – Series: 24.0V CT@ 1.040A Parallel: 12.0V @ 2.080A 4. Voltage Regulation: 20% TYP @ full load to no load Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements ...

Page 2

... VPL10-2500 VPL12-2000 25 12.6 1.980 6.30 25 16.0 1.570 8.00 VPL16-1600 C VPL20-1200 25 20.0 1.250 10.00 25 24.0 1.040 12.00 VPL24-1100 VPL25-1000 25 25.2 0.990 12.60 25 26.8 0.930 13.40 VPL26-930 VPL28-900 25 28.0 0.890 14.00 25 36.0 0.700 18.00 VPL36-700 VPL10-5000 50 10.0 5.000 5. ...

Page 3

Primary and secondary windings are designed ...