S8VS12024B Omron, S8VS12024B Datasheet - Page 17

Linear & Switching Power Supplies 24VDC 5A SW S/RUN

S8VS12024B

Manufacturer Part Number
S8VS12024B
Description
Linear & Switching Power Supplies 24VDC 5A SW S/RUN
Manufacturer
Omron
Datasheet

Specifications of S8VS12024B

Input Voltage
100 VAC to 240 VAC
Product
Switching
Commercial/medical
Both
Output Power Rating
120 W
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
5 A
Mounting Style
DIN Rail
Dimensions
121.3 mm L x 115 mm W x 50 mm H
Open Frame/enclosed
Enclosed
Power Supply Type
Switching
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
5A
Power Rating
120W
Length
121.3mm
Width
50mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
480-W Models
Standard Model
S8VS-48024
Models with Indication Monitor
S8VS-48024@
* The terminal arrangement is the same for models with screwless
Note: The illustration shows the S8VS-48024A model.
terminal blocks and standard models.
10
16
15
9
1
1
14
13
12
11
2
2
3
3
6
7
8
4
5
4
5
*1. The fuse is located on the (L) side. It is NOT user replaceable.
*2. This is the protective earth terminal specified in the safety standards.
*3. S8VS-48024A/B only.
*4. S8VS-48024A only.
*5. S8VS-48024B only.
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15,
16
Always ground this terminal.
AC Input terminals
(L), (N)
Protective Earth
terminal (PE)
DC Output terminals
(−V), (+V)
Output indicator
(DC ON: Green)
Output voltage adjuster
(V.ADJ)
Main display (Red) *3
Operation
indicator
(Orange) *3
Mode Key *3
Up Key *3
Down Key *3
Alarm
outputs
*3
NC (Not connected)
Name
Undervoltage
output terminal
(DC Low)
(Emitter side)
Undervoltage
output terminal
(DC Low)
(Collector side)
Maintenance
Forecast
output terminal
(Yrs) *4
(Emitter side)
Total run time
output terminal
(kh) *5
(Emitter side)
Maintenance
Forecast
output terminal
(Yrs) *4
(Collector side)
Total run time
output terminal
(kh) *5
(Collector side)
V
A
Apk
Yrs
kh
Connect the input lines to these
terminals. *1
Connect the ground line to this
terminal. *2
Connect the load lines to these
terminals.
Lights while a direct current (DC)
output is ON.
Use to adjust the voltage.
Indicates the measurement or set
value.
Lights up when the output voltage is
indicated. Blinks during setup of
undervoltage alarm value.
Lights up during indication of output
current.
Lights up during indication of peak
hold current.
Lights up during indication of
maintenance forecast monitor.
Blinks during setup of maintenance
forecast monitor setting. (S8VS-
48024A)
Lights up during indication of total
run time monitor. Blinks during setup
of total run time monitor. (S8VS-
48024B)
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
Use the Up Key to change to the
setting mode or to increase the set
value.
Use the Down Key to change to the
setting mode or to decrease the set
value.
Output when a drop is detected in
the output voltage (voltage drop =
transistor OFF).
Output when the set value for
maintenance is reached (transistor
OFF).
Output when the set value for total
run time is reached (transistor OFF).
Output when the set value for
maintenance is reached (transistor
OFF).
Output when the set value for total
run time is reached (transistor OFF).
Function
S8VS
17