S8VS12024B Omron, S8VS12024B Datasheet - Page 18

Linear & Switching Power Supplies 24VDC 5A SW S/RUN

S8VS12024B

Manufacturer Part Number
S8VS12024B
Description
Linear & Switching Power Supplies 24VDC 5A SW S/RUN
Manufacturer
Omron
Datasheet

Specifications of S8VS12024B

Input Voltage
100 VAC to 240 VAC
Product
Switching
Commercial/medical
Both
Output Power Rating
120 W
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
5 A
Mounting Style
DIN Rail
Dimensions
121.3 mm L x 115 mm W x 50 mm H
Open Frame/enclosed
Enclosed
Power Supply Type
Switching
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
5A
Power Rating
120W
Length
121.3mm
Width
50mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Mode Change (S8VS-@@@24A@@/S8VS-@@@24B@@/S8VS-@@@24BE@ Only)
S8VS-@@@24A@@ models (with display monitor) can display the output voltage, output current, peak hold current, or maintenance forecast
monitor time. S8VS-@@@24B@@/S8VS-@@@24BE@ models (with display monitor) can display the output voltage, output current, peak hold
current, or total run time.
Note: No setting mode is provided for the S8VS-06024@.
Operation Mode
Various states of the Power Supply are indicated.
Note: 1. The peak hold current starts measuring the current 3 seconds after the Power Supply is started. Inrush current is thus not measured.
Setting Mode (Except for S8VS-06024@)
Set various parameters of the Power Supply.
Note: 1. Press and hold the (9) Up Key U or (10) Down Key D for two seconds or more to increase or decrease the value rapidly.
Press and hold
Up key
for three seconds or more.
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Undervoltage
detected
Operation Mode
Maintenance
forecast
2. For the factory setting, the output voltage will be displayed when the power supply is first turned ON. Thereafter, the output voltage will
2. The S8VS-06024@ is not provided with the setting mode and its parameters are fixed at the shipment setting.
Press 3 seconds
or more.
U
be indicated in the same display when shutting down.
or Down Key
or
Operation mode
D
Setting mode
Power-ON
Maintenance forecast monitor
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
Output current
(Current output by Power Supply is
monitored and displayed.)
Peak hold current (See note 1.)
(Maximum current output by Power Supply is
recorded and displayed.)
pressed for 30 seconds or more.
Model indication
Press Mode key
hold for three seconds or more.
Or no key operation for 30 seconds or more.
Press 3 seconds or more or no key
/
/
* Factory settings are in reverse
0.1-V steps
0.5-year steps
18.5 to
0.0 to
type.
and
0.5
20.0
*
*
to 5.0 (y)
to 27.5 (V)
Models with Total Run Time Monitor (S8VS-@@@24B@@/S8VS-@@@24BE@)
Undervoltage
detected
Total run
time
Operation Mode
Models with Total Run Time Monitor (S8VS-@@@24B@@/
S8VS-@@@24BE@)
Press 3 seconds
or more.
o r
Total run time monitor
pressed for 30 seconds or more.
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
Output current
(Current output by Power Supply is
monitored and displayed.)
Peak hold current
(Maximum current output by Power Supply is
recorded and displayed.)
Press 3 seconds or more or no key
/
/
* Factory settings are in
0.1-V steps
1,000-hour steps
1 to
18.5 to
reverse type.
50
*
to 150 ( × 1000 h)
20.0
*
S8VS
to 27.5 (V)
18

Related parts for S8VS12024B