RPS-75-12 Mean Well, RPS-75-12 Datasheet

Linear & Switching Power Supplies 75.6W 12V 6.3A

RPS-75-12

Manufacturer Part Number
RPS-75-12
Description
Linear & Switching Power Supplies 75.6W 12V 6.3A
Manufacturer
Mean Well
Datasheet

Specifications of RPS-75-12

Output Power Rating
76 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
6.3 A
Mounting Style
Screw
Dimensions
127 mm L x 76.2 mm W x 31 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD (23.5CFM)
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
EMI CONDUCTION & RADIATION
75W Single Output Medical Type
Note.3
Note.2
RPS-75-3.3
3.3V
15A
0 ~ 20A
49.5W
66W
80mVp-p
2.9 ~ 3.6V
500ms, 30ms/230VAC
80ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
1.5A/115VAC
140 ~ 180%
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
3.8 ~ 4.46V
Protection type : Shut down o/p voltage, re-power to recover
-20 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A
446.8K hrs min.
127*76.2*31mm (L*W*H)
0.26Kg; 63pcs/16.3Kg/1.35CUFT
73%
COLD START 25A/115VAC
Earth leakage current <200uA / 264VAC, Patient
2.0%
0.5%
1.5%
0.03%/
(0 ~ 45
rated output power
(Refer to output load derating curve)
RPS-75-5
I/P-FG:1.5KVAC
5V
14A
0 ~ 18.7A
70W
94W
80mVp-p
4.75 ~ 5.5V
127 ~370VDC
78%
5.75 ~ 6.75V
1A/230VAC
MIL-HDBK-217F (25 )
2.0%
0.5%
1.5%
20ms/115VAC at full load
500ms, 30ms/115VAC at full load
50A/230VAC
RPS-75-12
12V
6.3A
0 ~ 8.3A
75.6W
99.6W
120mVp-p
11.4 ~ 13.2V
O/P-FG:1.5KVAC
82%
13.8 ~ 16.2V
1.0%
0.5%
1.0%
leakage current
RPS-75-15
0 ~ 6.7A
75W
100.5W
150mVp-p
13.5 ~ 16.5V
15V
5A
17.25 ~ 20.25V
83%
1.0%
0.5%
1.0%
<100uA/264VAC
RPS-75-24
24V
3.2A
0 ~ 4.2A
76.8W
100.8W
240mVp-p
22.8 ~ 27.6V
27.6 ~ 32.4V
85%
1.0%
0.5%
1.0%
R P S - 7 5
RPS-75-36
36V
2.1A
0 ~ 2.8A
75.6W
100.8W
300mVp-p
34.2 ~ 39.6V
41.4 ~ 48.6V
86%
0.5%
1.0%
1.0%
File Name:RPS-75-SPEC 2011-03-31
EN60601-1
IEC60601-1
RPS-75-48
48V
1.6A
0 ~ 2.1A
76.8W
100.8W
300mVp-p
45.6 ~ 52.8V
55.2 ~ 64.8V
86%
1.0%
0.5%
1.0%
s e r i e s

Related parts for RPS-75-12

RPS-75-12 Summary of contents

Page 1

... Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A MTBF 446.8K hrs min. OTHERS DIMENSION 127*76.2*31mm (L*W*H) 0.26Kg; 63pcs/16.3Kg/1.35CUFT PACKING NOTE RPS-75-5 RPS-75-12 5V 12V 14A 6. 18. 8.3A 70W 75.6W 94W 99.6W 80mVp-p 120mVp-p 4 ...

Page 2

... RS- RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. 95 100 115 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz File Name:RPS-75-SPEC 2011-03- Unit:mm Terminal JST SVH-21T-P1.1 or equivalent Terminal JST SVH-21T-P1.1 or equivalent Terminal JST SXH-001T-P0.6 or equivalent fosc : 65KHz + Ta=25 240 264 ...

Related keywords