RPS-60-24 Mean Well, RPS-60-24 Datasheet

Linear & Switching Power Supplies 60W 24V 2.5A

RPS-60-24

Manufacturer Part Number
RPS-60-24
Description
Linear & Switching Power Supplies 60W 24V 2.5A
Manufacturer
Mean Well
Datasheet

Specifications of RPS-60-24

Output Power Rating
60 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
2.5 A
Mounting Style
Screw
Dimensions
101.6 mm L x 50.8 mm W x 29 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RPS-60-24
Manufacturer:
MWL
Quantity:
1 202
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 5)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD(10sec.)
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
60W Single Output Medical Type
Note.4
Note.3
Note.2
RPS-60-3.3
3.3V
10A
0 ~ 11A
33W
36.3W
80mVp-p
3.1 ~ 3.6V
500ms, 30ms/230VAC
50ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
0.15Kg; 96pcs/15.4Kg/0.89CUFT
74%
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 5V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25 / 70% RH
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
353.6Khrs min.
101.6*50.8*29mm (L*W*H)
1.8A/115VAC
COLD START 60A/230VAC
For earth <200uA / 264VAC, For patient <100uA/264VAC
2.0%
0.5%
1.0%
0.03%/
(0 ~ 45 )
(Refer to output load derating curve)
127 ~ 370VDC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
13ms/115VAC at full load
1 A/230VAC
RPS-60-5
5V
10A
0 ~ 11A
50W
55W
80mVp-p
4.75 ~ 5.5V
5.75 ~ 6.75V
79%
2.0%
0.5%
1.0%
500ms, 30ms/115VAC at full load
30A/115VAC
O/P-FG:1.5KVAC
RPS-60-12
12V
5A
0 ~ 5.5A
60W
66W
120mVp-p
11.4 ~ 13.2V
83%
13.8 ~ 16.2V
2.0%
0.5%
1.0%
RPS-60-15
15V
4A
0 ~ 4.4A
60W
66W
150mVp-p
13.5 ~ 16.5V
84%
17.25 ~ 20.25V
2.0%
0.5%
1.0%
R P S - 6 0
RPS-60-24
24V
2.5A
0 ~ 2.75A
60W
66W
240mVp-p
22.8 ~ 27.6V
85%
28.4 ~ 32.4V
1.0%
0.5%
1.0%
EN60601-1
IEC60601-1
File Name:RPS-60-SPEC 2011-03-31
RPS-60-48
48V
1.25A
0 ~ 1.375A
60W
66W
300mVp-p
45.6 ~ 52.8V
86%
55.2 ~ 64.8V
1.0%
0.5%
1.0%
s e r i e s

Related parts for RPS-60-24

RPS-60-24 Summary of contents

Page 1

... A/230VAC 30A/115VAC 5.75 ~ 6.75V 13.8 ~ 16.2V (Refer to output load derating curve) 0.03 I/P-FG:1.5KVAC O/P-FG:1.5KVAC MIL-HDBK-217F ( EN60601-1 IEC60601-1 RPS-60-15 RPS-60-24 RPS-60-48 15V 24V 48V 4A 2.5A 1.25A 2.75A 0 ~ 1.375A 60W 60W 60W 66W 66W 66W 150mVp-p ...

Page 2

... HS2 SVR1 CN2 4- 3.3 Assignment Mating Housing Terminal +V JST VHR JST SVH-21T-P1.1 or equivalent or equivalent -V fosc : 100KHz RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. 95 100 115 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz File Name:RPS-60-SPEC 2011-03- Unit: Ta=25 240 264 ...