TWR-5/3000-12/500-D48A-C Murata Power Solutions Inc, TWR-5/3000-12/500-D48A-C Datasheet - Page 6

DC/DC Converters & Regulators 20W +/-5/+/-12V

TWR-5/3000-12/500-D48A-C

Manufacturer Part Number
TWR-5/3000-12/500-D48A-C
Description
DC/DC Converters & Regulators 20W +/-5/+/-12V
Manufacturer
Murata Power Solutions Inc
Series
TWRr
Datasheet

Specifications of TWR-5/3000-12/500-D48A-C

Output Power
15 W
Input Voltage Range
18 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
500 mA
Output Voltage (channel 3)
+/- 12 V
Isolation Voltage
1.5 KV
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
TWR-5/3000-12/500-D48A-C
LINE REGULATION
+12.150
+12.125
+12.100
+12.075
+12.050
+12.025
+12.000
+11.975
–12.025
–12.050
–12.075
–12.100
–12.125
–12.150
–12.175
–12.200
+5.010
+5.005
+5.000
+4.995
+4.990
+4.985
+4.980
+4.975
18
18
18
+12V Line Regulation
(+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA))
-12V Line Regulation
(+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA))
+5V Line Regulation
(+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA))
24
24
24
36
36
36
Input Voltage (V)
Input Voltage (V)
Input Voltage (V)
48
48
48
www.murata-ps.com
60
60
60
72
72
72
If you’re designing with EMC in mind, note that all of MPS’s TWR 20 Watt
A-Series DC/DC Converters have been characterized for radiated and con-
ducted emissions in our new EMI/EMC laboratory. Testing is conducted in
an EMCO 5305 GTEM test cell utilizing EMCO automated EMC test software.
Radiated emissions are tested to the limits of FCC Part 15, Class B and
CISPR 22 (EN 55022) Class B. Correlation to other specifications can be
supplied upon request. Radiated emissions plots to FCC and CISPR 22 for
model TWR-5/3000-15/500-D12A appear below. Its performance is typical
of all models in the Series. Published EMC test reports are available for
each model number. Contact MPS’s Applications Engineering for details.
EMI RADIATED EMISSIONS
–10
–20
–10
–20
80
70
60
50
40
30
20
10
80
70
60
50
40
30
20
10
0
0
Converter Output = +5Vdc @ 2.7A and ±15Vdc @ ±450mA
Converter Output = +5Vdc @ 2.7A and ±15Vdc @ ±450mA
TWR-5/3000-15/500-D12A Radiated Emissions
TWR-5/3000-15/500-D12A Radiated Emissions
Technical enquiries email: sales@murata-ps.com, tel:
FCC Part 15 Class B, 3 Meters
EN 55022 Class B, 10 Meters
100
100
20W, Triple Output DC/DC Converters
FCC Class B Li mi t
EN 55022 Class B Li mi t
Radiated Emissions
Radiated Emissi ons
Frequency (MHz)
Frequency (MHz )
TWR A-Series
MDC_TWR20W.B03
+1 508 339 3000
Page 6 of 8
1000
1000

Related parts for TWR-5/3000-12/500-D48A-C