TWR-5/3000-15/500-D12A-C Murata Power Solutions Inc, TWR-5/3000-15/500-D12A-C Datasheet
TWR-5/3000-15/500-D12A-C
Specifications of TWR-5/3000-15/500-D12A-C
Available stocks
Related parts for TWR-5/3000-15/500-D12A-C
TWR-5/3000-15/500-D12A-C Summary of contents
Page 1
... PWM CONTROL CONTROLLER (4) ISOLAT ION www.murata-ps.com TWR A-Series 20W, Triple Output DC/DC Converters durability is substantiated by a rigorous in-house qualification program that includes HALT (Highly Accelerated Life Testing). Each device has a +5V primary output and either ±12V or ±15V auxiliary outputs. “D12A” models achieve fully rated performance with inputs ranging from Volts. “ ...
Page 2
... Input Voltage Range: D12 = 9-36V (12V nominal) D48 = 18-75V (48V nominal) Maximum Auxilliary Output: Currents in mA from each output * Contact Murata Power Solutions for availability 100 www.murata-ps.com TWR A-Series 20W, Triple Output DC/DC Converters Input 4 Efficiency V Nom. Range (Volts) (Volts) (mA) Min. 12 ...
Page 3
... Performance/Functional Specifications Table is not implied. Technical Notes Filtering and Noise Reduction All A-Series TWR 20 Watt DC/DC Converters achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output noise may be further reduced by installing electrolytic capacitors across the input terminals and/or low-ESR tantalum or electrolytic capacitors across the output terminals ...
Page 4
... The performance curves below were derived from actual test data for a single model number (TWR-5/3000-12/250-D48). Since all devices in this series have the same circuit architecture, the performance curves are representative for all devices. Efficiency vs. Input Voltage (+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA) 84 ...
Page 5
... V –12.90 –13.05 –13.20 200 250 25 TWR A-Series 20W, Triple Output DC/DC Converters +5V Output Load Regulation (±12V outputs loaded @ ±250mA 0.75 1.25 1.75 +5V Output Current (A) +12V Output Load Regulation (+5V outputs loaded @ 2.75A ...
Page 6
... Input Voltage (V) EMI RADIATED EMISSIONS If you’re designing with EMC in mind, note that all of MPS’s TWR 20 Watt A-Series DC/DC Converters have been characterized for radiated and con- ducted emissions in our new EMI/EMC laboratory. Testing is conducted in an EMCO 5305 GTEM test cell utilizing EMCO automated EMC test software. ...
Page 7
... Over time, this system has helped refine our assembly operation to yield one of the lowest product defect rates in the industry. www.murata-ps.com TWR A-Series 20W, Triple Output DC/DC Converters Qualification Testing Method/Comments MPS in-house procedure Max. rated temp., 1,000 hours 10 cycles, – ...
Page 8
... Watt Converter Operational Details There are several operational details of the 20W TWR series to be aware of when applying these converters. 20 Watts maximum power The total maximum power for all outputs is 20 Watts. This is the sum of each separate output. Any one output may achieve its maximum power as long as the sum of all outputs for the whole converter does not exceed 20 Watts ...