CPA550-4530G POWER ONE, CPA550-4530G Datasheet
CPA550-4530G
Specifications of CPA550-4530G
Related parts for CPA550-4530G
CPA550-4530G Summary of contents
Page 1
Watt CompactPCI ® Description The CPA and CPD Series are highly reliable power supplies ® for CompactPCI systems, which are increasingly used in communications, industrial, military, aerospace, and other applications. These power supplies offer high power density ...
Page 2
... Vo2 3.3 Vo3 12 Vo4 –12 CPA500-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA550-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 1 The sum of the power of all outputs may not exceed the total power for the specified required forced-air cooling. 2 Efficiency ° ...
Page 3
Watt CompactPCI ® Product Marking Label with specific type designation, applicable safety approvals and recognition marks, CE mark, warnings, Power-One patents, company logo, input voltage range, Functional Description The inputs of all converters are protected against surges ...
Page 4
Watt CompactPCI ® technique and proprietary leading and trailing-edge pulse- width modulation. It has a proven track record in high- availability power solutions. The switching frequency is typically 135 kHz. Some models (CPx200/250 version V117, CPA500/550 version ...
Page 5
... Rated input frequency: 50 – 60 Hz, operating input frequency range: 47 – First value for CPD/CPA200, 2 value for CPD/CPA250 3 nd First value for CPA500, 2 value for CPA550 4 Short interruption of V without affecting the outputs i 5 CPA200/250 with version V117 or higher, as they are equipped with an input voltage trigger BCD20005-G Rev. AF, 18-Aug-10 ...
Page 6
Watt CompactPCI ® Input Fuse and Reverse Polarity Protection A metal oxide varistor (voltage dependent resistor VDR) together with the input filter form an effective protection against high input voltage transients, which typically occur in most installations. ...
Page 7
Watt CompactPCI ® Electrical Output Data General Conditions for table 4: – °C, unless T is specified – CPD/CPA200: 250 LFM (1.25 m/s), CPD/CPA250: 400 LFM (2 m/s) – Sense lines connected ...
Page 8
... Watt CompactPCI ® General conditions for table 5: – °C, unless T is specified – CPD500, CPA500: 300 LFM (1.5 m/s), CPA550: 400 LFM (2 m/s) – Sense lines connected directly at the connector Table 5 a: Output data of CPD500 and CPA500/550 Output Characteristics Conditions V Output voltage ...
Page 9
Watt CompactPCI ® Hold-up Time of CPD Models For extended hold-up time of CPD models, use external output capacitors or decoupling diodes and input capacitors of adequate size. Formula for additional external input capacitor: 2 • P ...
Page 10
... Watt CompactPCI ® nom 300 LFM = 1.5 m/s (CPA/CPD500) 400 LFM = 2 m/s (CPA550) JM012a 1.0 Convection cooling in upright position CPA/CPD500 0.6 0.5 CPA550 min Fig. 4c Output power versus (CPA500/550, CPD500 nom Caution: The installer must ensure that under all operating ...
Page 11
Watt CompactPCI ® Temperature Warning and Shutdown A temperature warning circuitry monitors the case temperature T . Its output signal low impedance, when the T exceeds the upper threshold C level, and changes back ...
Page 12
Watt CompactPCI ® Active Current Sharing for Vo1, Vo2, Vo3 The current share facility, consisting of a single-wire link, should be used, where several converters are operated in parallel connection, for example, high reliability n+1 redundant systems ...
Page 13
Watt CompactPCI ® Electromagnetic Compatibility (EMC) A metal oxide VDR together with the input fuse and a filter form an effective protection against high input voltage Electromagnetic Immunity Table 8: Immunity type tests Phenomenon Standard Level Electrostatic ...
Page 14
Watt CompactPCI ® Electromagnetic Emission Radiated and conducted emissions comply with EN 55011/ 55022, class A. In addition, CPD500 and CPA500/550 meet conducted emissions class B. dBµV CPD200, B738613, 50807-TU, Peak L, Conducted 0. MHz, ...
Page 15
Watt CompactPCI ® Immunity to Environmental Conditions Table 9: Mechanical and climatic stress (tests of CPD500 are in process) Test method Standard Cab Damp heat IEC/EN 60068-2-78 steady state Ea Shock IEC/EN 60068-2-27 (half-sinusoidal) Eb Bump IEC/EN ...
Page 16
Watt CompactPCI ® Mechanical Data Dimensions in mm (inches) Fig. 15 CPA200/250 and CPD200/250. Overall size: 162.5 x 128.7 x 40.6 mm. Weight: 0.8 kg (0.098") Fig. 16 View of the connector Fig. 17 CPD500 and CPA500/550. ...
Page 17
Watt CompactPCI ® Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the Positronic connector. Pin no. 45 (protective earth leading pin, ...
Page 18
Watt CompactPCI ® Table 13: Isolation Characteristic Electric Actual factory test 1 s strength AC test voltage equivalent test to factory test Insulation resistance at 500 VDC 1 According to IEC/EN 60950, subassemblies connecting input to output ...
Page 19
Watt CompactPCI ® Options L: Output Current Latch All CPA/CPD models exhibit a latching shutdown, which is activated if only one output voltage is too high; see Output Characteristic and Protection. If option L is fitted, this ...