Specifications of G9EC-1-B-DC24

Contact Form
SPST - NO
Coil Voltage
24 VDC
Contact Rating
200 A
Coil Termination
Screw Terminals
Contact Termination
Screw
Power Consumption
11 W
Coil Current
469 mA
Coil Resistance
51.2 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G9EC1B24DC OMRG9EC1B24DC
Specifications
■ Ratings
Coil
Note: 1. The figures for the rated current and coil resistance are for a coil temperature of 23 ° C and have a tolerance of ± 10%.
Contacts
■ Characteristics
Note: 1. The above values are initial values at an ambient temperature of 23 ° C unless otherwise specified.
12
12 VDC
24 VDC
48 VDC
60 VDC
100 VDC
Rated load
Rated carry current
Maximum switching voltage
Maximum switching current
Contact resistance (See note 2.)
Contact voltage drop
Operate time
Release time
Insulation resistance
(See note 3.)
Dielectric strength
Impulse withstand voltage (See note 4.)
Vibration resistance
Shock resistance
Mechanical endurance (See note 5.)
Electrical endurance (resistive load) (See note 6.)
Short-time carry current
Maximum interruption current
Overload interruption
Reverse polarity interruption
Ambient operating temperature
Ambient operating humidity
Weight
Rated voltage
2. The figures for the operating characteristics are for a coil temperature of 23 ° C.
3. The figure for the maximum voltage is the maximum voltage that can be applied to the relay coil.
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The insulation resistance was measured with a 500-VDC megohmmeter.
4. The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 × 50 µ s).
5. The mechanical endurance was measured at a switching frequency of 3,600 operations/hr.
6. The electrical endurance was measured at a switching frequency of 60 operations/hr.
Item
DC Power Relays (200-A Models)
938 mA
469 mA
234 mA
188 mA
113 mA
Rated current
Between coil and contacts
Between contacts of the same polarity
Between coil and contacts
Between contacts of the same polarity
Destruction
Malfunction
Destruction
Malfunction
Item
200 A at 400 VDC
200 A
400 V
200 A
12.8 Ω
51.2 Ω
888.9 Ω
204.8 Ω
320.0 Ω
Coil resistance
Resistive load
G9EC-1(-B)
G9EC-1
75% max. of rated
voltage
Must-operate
30 m Ω max. (0.2 m Ω typical)
0.1 V max. (for a carry current of 200 A)
50 ms max.
30 ms max.
1,000 M Ω min.
1,000 M Ω min.
2,500 VAC, 1 min
2,500 VAC, 1 min
4,500 V
10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s
10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s
490 m/s
196 m/s
200,000 operations min.
400 VDC, 200 A, 3,000 operations min.
300 A (15 min)
1,000 A at 400 VDC (10 times)
700 A at 400 VDC (40 times min.)
− 200 A at 200 VDC (1,000 times min.)
− 40 to 50 ° C (with no icing or condensation)
5% to 85%
Approx. 560 g
voltage
2
2
8% min. of rated
voltage
Must-release
voltage
G9EC-1(-B)
110% of rated volt-
age (at 23°C within
10 minutes)
Maximum voltage
(See note 3.)
Approx. 11 W
consumption
Power
2