LIS331HH STMicroelectronics, LIS331HH Datasheet - Page 29

Board Mount Accelerometers MEMS Digital Sensor 3-axes Nano

LIS331HH

Manufacturer Part Number
LIS331HH
Description
Board Mount Accelerometers MEMS Digital Sensor 3-axes Nano
Manufacturer
STMicroelectronics
Datasheet

Specifications of LIS331HH

Sensing Axis
X, Y, Z
Acceleration
6 g, 12 g, 24 g
Digital Output - Number Of Bits
16 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Supply Current
10 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Shutdown
Yes
Sensitivity
3 mg/digit, 6 mf/digit, 12 mg/digit
Package / Case
LGA-16
Output Type
Digital
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LIS331HH
Quantity:
54
Part Number:
LIS331HHTR
Manufacturer:
APT
Quantity:
430
Part Number:
LIS331HHTR
Manufacturer:
ST
0
Part Number:
LIS331HHTR
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
LIS331HHTR
Quantity:
1 000
Company:
Part Number:
LIS331HHTR
Quantity:
3 000
LIS331HH
7.8
7.9
Table 33.
This register sets the acceleration value taken as a reference for the high-pass filter output.
When filter is turned on (at least one of FDS, HPen2, or HPen1 bit is equal to ‘1’) and HPM
bits are set to “01”, filter out is generated taking this value as a reference.
STATUS_REG (27h)
Table 34.
Table 35.
OUT_X_L (28h), OUT_X_H (29)
X-axis acceleration data. The value is expressed as two’s complement.
Ref7 - Ref0
ZYXOR
ZOR
YOR
XOR
ZYXDA
ZDA
YDA
XDA
ZYXOR
REFERENCE description
STATUS_REG register
STATUS_REG description
X, Y and Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data has overwritten the previous one before it was read)
Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Z-axis has overwritten the previous one)
Y axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Y-axis has overwritten the previous one)
X axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the X-axis has overwritten the previous one)
X, Y and Z axis new data available. Default value: 0
(0: a new set of data is not yet available; 1: a new set of data is available)
Z axis new data available. Default value: 0
(0: a new data for the Z-axis is not yet available;
1: a new data for the Z-axis is available)
Y axis new data available. Default value: 0
(0: a new data for the Y-axis is not yet available;
1: a new data for the Y-axis is available)
X axis new data available. Default value: 0
(0: a new data for the X-axis is not yet available;
1: a new data for the X-axis is available)
Reference value for high-pass filter. Default value: 00h.
ZOR
YOR
Doc ID 16366 Rev 1
XOR
ZYXDA
ZDA
Register description
YDA
XDA
29/37

Related parts for LIS331HH