Specifications of LIS35DE

Sensing Axis
Triple
Acceleration
2 g, 8 g
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Supply Current
0.3 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Shutdown
Yes
Sensitivity
18 mg/digit, 72 mg/digit
Package / Case
LGA-14
Output Type
Digital
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LIS35DE
Manufacturer:
STM
Quantity:
5 531
Part Number:
LIS35DETR
Manufacturer:
ST
0
Part Number:
LIS35DETR
Manufacturer:
ST
Quantity:
20 000
Part Number:
LIS35DETR-ST
Manufacturer:
ST
0
LIS35DE
7.12
7.13
FF_WU_DURATION_1 (33h)
Table 36.
Table 37.
Duration register for Free-Fall/Wake-Up interrupt 1. Duration step and maximum value
depend on the ODR chosen. Step 2.5 msec, from 0 to 637.5 msec if ODR=400Hz, else step
10 msec, from 0 to 2.55 sec when ODR=100Hz. The counter used to implement duration
function is blocked when LIR=1 in configuration register and the interrupt event is verified
FF_WU_CFG_2 (34h)
Table 38.
Table 39.
D7 - D0
AOI
LIR
ZHIE
ZLIE
YHIE
YLIE
XHIE
XLIE
AOI
D7
FF_WU_DURATION_1 (33h) register
FF_WU_DURATION_1 (33h) register description
FF_WU_CFG_2 (34h) register
FF_WU_CFG_2 (34h) register description
And/Or combination of Interrupt events. Default value: 0
(0: OR combination of interrupt events; 1: AND combination of interrupt events)
Latch Interrupt request into FF_WU_SRC reg with the FF_WU_SRC reg cleared by
reading FF_WU_SRC_2 reg. Default value: 0
(0: interrupt request not latched; 1: interrupt request latched)
Enable interrupt generation on Z high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
LIR
D6
Duration value. Default value: 0000 0000
ZHIE
D5
Doc ID 15594 Rev 1
ZLIE
D4
YHIE
D3
YLIE
D2
Register description
XHIE
D1
XLIE
D0
31/39