UTS10DCG Souriau Connection Technology, UTS10DCG Datasheet - Page 38

CONN RCPT SEALING CAP SIZE 10

UTS10DCG

Manufacturer Part Number
UTS10DCG
Description
CONN RCPT SEALING CAP SIZE 10
Manufacturer
Souriau Connection Technology
Series
Trim Trio® UTSr
Datasheets

Specifications of UTS10DCG

Accessory Type
Cap (Cover), Sealing
Shell Size - Insert
10
Features
Metal Chain
Color
Black
Mil Type
MIL-DTL-26482 I
Product Type
Dustcaps
Shell Style
Receptacle
Shell Size
10
Mounting Style
Through Hole
Termination Style
Screw
Mounting Angle
Straight
Connector Shell Size
10
Connector Body Material
Plastic
Body Material
Plastic
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Trim Trio® UTS Receptacle
For Use With
SOU1525 - CONN RCPT JAM NUT 6POS W/SCKTSOU1524 - CONN RCPT JAM NUT 6POS W/PINSOU1290 - CONN RCPT 6X1.0 MALE JAM NUTSOU1289 - CONN RCPT 4X1.6 MALE JAM NUTSOU1288 - CONN RCPT 3X1.6 MALE JAM NUTSOU1281 - CONN RCPT 6X1.0 FEMALE JAM NUTSOU1280 - CONN RCPT 4X1.6 FEMALE JAM NUTSOU1279 - CONN RCPT 3X1.6 FEMALE JAM NUT
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SOU1315
<<
UTS Series
#1 6 coaxial contacts
Multipiece male contact with coax cable
Multipiece kit details
Note : all dimensions are in mm
AMPHENOL
RG1 78A/U
surprenant
reference
RG1 88/U
RG1 74/U
RG1 61U
RG1 87U
RG1 96U
pn 81 34
21 -598
RG1 79
Contact assembly with dielectric diameter over 1 .4mm - without inner supporting sleeve
Contact assembly with dielectric diameter under 1 .4mm - with inner supporting sleeve
Cable
RMDXK1 0D28
Step 1:
- Assemble outer hyring onto cable
- Assemble supporting sleeve over dielectric and under braid
- Assemble inner socket to inner conductor, push back against
sleeve and crimp
includes
Step 1:
- Assemble outer hyring onto cable
- Assemble inner socket to inner conductor and crimp
RMDXK10D28
Outer contact
Male:
Outer male contact
RMDX60-2
RMDX602D28
RFD26L1D28
RMDXB0553
YOC-074
Outer male contact
RMDX60-2
Supporting
sleeve
compoments
RMDXB0553
Hyring com-
plementary
YOC074 +
YOC074
YOC074
Outer hyring
M10S-1J
Crimp
Inner supporting
tool
Inner contact
Body contact
Outer hyring
Step 2:
- Insert the assembly into the outer male contact
- The cable braid (shield) should now cover the
until the inner socket snaps into place
barrel of the outer male contact as shown
sleeve
Step 2:
- Insert the assembly into the outer male contact
- The cable braid (shield) should now cover the
until the inner socket snaps into place
barrel of the outer male contact as shown
Die set
S22-1
Inner socket
RFD26L-1
Inner socket
RFD26L-1
bushing
74
SL47-1
Stop
Inner supporting
sleeve
RMDXB-055-3
RFD26L1D28
contact
Inner
Outer hyring
YOC-074
Cable stip length
Dielectric
diameter
Step 3:
- Slide outer hyring forward against spring and
crimp in place as shown
Outer hyring
YOC-074
Die set
S23D2
S26D2
S23D2
Step 3:
- Slide outer hyring forward against spring and
4.37
-
-
crimp in place as shown
A
7.95
B
±0.41
±0.41
Locking louver typical
C
bushing
SL46D2
1 5.88
Stop
Grounding louver typical
7.54
9.1 2
Locking louver typical
±0.41
±0.41
±0.41
Grounding louver typical
1 7.53
Strip lengths
of cable
4.37
4.37
4.37
4.37
4.37
7.54
7.54
4.37
4.37
A
±0.41
Cable strip length
Strip lengths
of cable
7.95
7.95
7.95
7.95
7.95
7.95
7.95
9.1 2
9.1 2
B
1 5.88
1 5.88
1 5.88
1 5.88
1 5.88
1 7.53
1 7.53
1 5.88
1 5.88
C
UTS Series
Multipiece female contact with coax cable
Multipiece kit details
Note : all dimensions are in mm
AMPHENOL
RG1 78A/U
surprenant
reference
RG1 88/U
RG1 74/U
RG1 61U
RG1 87U
RG1 96U
pn 81 34
21 -598
RG1 79
Contact assembly with dielectric diameter over 1 .4mm - without inner supporting sleeve
Contact assembly with dielectric diameter under 1 .4mm - with inner supporting sleeve
Cable
RCDXK1D28
includes
Step 1:
- Assemble outer hyring onto cable
- Assemble supporting sleeve over dielectric and under braid
- Assemble inner pin to inner conductor, push back against
sleeve and crimp
Step 1:
- Assemble outer hyring onto cable
- Assemble inner pin to inner conductor and crimp
Outer contact
RCDXK1D28
Female:
Outer hyring
RMD26L1D28
Strip lengths
of cable
RCDX602D28
RCDXB0553
YOC-074
compoments
RMDXB0553
Hyring com-
plementary
Strip lengths
of cable
YOC074 +
YOC074
YOC074
1 1.1 3
Supporting
sleeve
±0.41
6.35
1 1.1 3
M10S-1J
Crimp
Inner supporting
±0.41
tool
±0.41
Inner contact
Body contact
Outer hyring
Step 2:
- Insert the assembly into the outer female contact
- The cable braid (shield) should now cover the
until the inner pin snaps into place
barrel of the outer female contact as shown
sleeve
4.37
Step 2:
- Insert the assembly into the outer female contact
- The cable braid (shield) should now cover the
±0.41
Outer hyring
YOC-074
until the inner pin snaps into place
barrel of the outer female contact as shown
Die set
S22-1
Outer hyring
YOC-074
bushing
75
SL47-1
Stop
Supporting sleeve
RCDXB-055-1
RMD26L1D28
Inner pin
RMD26L-1
contact
Inner
Cable stip length
Dielectric
diameter
Inner pin
RMD26L-1
Step 3:
- Slide outer hyring forward against spring and
crimp in place as shown
Die set
S23D2
S23D2
S23D2
Outer female contact
RCDX60-2
Step 3:
- Slide outer hyring forward against spring and
-
-
A
crimp in place as shown
B
C
bushing
SL46D2
Stop
Outer female contact
RCDX60-2028
4.37
4.37
4.37
4.37
4.37
6.35
6.35
4.37
4.37
A
Cable strip length
B
-
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
C
>>

Related parts for UTS10DCG