A3P1000-FGG256 Actel, A3P1000-FGG256 Datasheet - Page 15

no-image

A3P1000-FGG256

Manufacturer Part Number
A3P1000-FGG256
Description
FPGA - Field Programmable Gate Array 1M System Gates
Manufacturer
Actel
Datasheet

Specifications of A3P1000-FGG256

Processor Series
A3P1000
Core
IP Core
Maximum Operating Frequency
350 MHz
Number Of Programmable I/os
300
Data Ram Size
147456
Delay Time
11.1 ns
Supply Voltage (max)
1.575 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Development Tools By Supplier
A3PE-Proto-Kit, A3PE-Brd1500-Skt, Silicon-Explorer II, Silicon-Sculptor 3, SI-EX-TCA, FlashPro 4, FlashPro 3, FlashPro Lite
Mounting Style
SMD/SMT
Supply Voltage (min)
1.425 V
Number Of Gates
1000 K
Package / Case
FPBGA-256
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A3P1000-FGG256
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
A3P1000-FGG256
Manufacturer:
ACTEL
Quantity:
20 000
Part Number:
A3P1000-FGG256I
Manufacturer:
AC2
Quantity:
90
Part Number:
A3P1000-FGG256I
Manufacturer:
ACTEL
Quantity:
1
Part Number:
A3P1000-FGG256I
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
A3P1000-FGG256I
Manufacturer:
MICROSEMI/美高森美
Quantity:
20 000
Part Number:
A3P1000-FGG256T
Manufacturer:
Microsemi SoC
Quantity:
10 000
2 – ProASIC3 DC and Switching Characteristics
General Specifications
Table 2-1 • Absolute Maximum Ratings
Symbol
VCC
VJTAG
VPUMP
VCCPLL Analog power supply (PLL)
VCCI
VMV
VI
T
T
Notes:
1. The device should be operated within the limits specified by the datasheet. During transitions, the input signal may
2. For flash programming and retention maximum limits, refer to
STG
J
2
undershoot or overshoot according to the limits shown in
limits, refer to
2
DC core supply voltage
JTAG DC voltage
Programming voltage
DC I/O output buffer supply voltage
DC I/O input buffer supply voltage
I/O input voltage
Storage temperature
Junction temperature
Operating Conditions
Stresses beyond those listed in
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Absolute Maximum Ratings are stress ratings only; functional operation of the device at these or any
other conditions beyond those listed under the Recommended Operating Conditions specified in
Table 2-2 on page 2-2
Table 2-2 on page
Parameter
2-2.
is not implied.
Table 2-1
(when I/O hot insertion mode is enabled)
–0.3 V to (VCCI + 1 V) or 3.6 V, whichever voltage is lower
(when I/O hot-insertion mode is disabled)
may cause permanent damage to the device.
R e v i s i o n 9
Table 2-4 on page
Table 2-3 on page
–0.3 V to 3.6 V
–65 to +150
–0.3 to 1.65
–0.3 to 3.75
–0.3 to 3.75
–0.3 to 1.65
–0.3 to 3.75
–0.3 to 3.75
2-3.
Limits
+125
2-2, and for recommended operating
Units
°C
°C
V
V
V
V
V
V
V
2 -1