BH1715FVC-TR Rohm Semiconductor, BH1715FVC-TR Datasheet - Page 5

Industrial Optical Sensors Ambient Light Sensor Digital 16Bit Serial

BH1715FVC-TR

Manufacturer Part Number
BH1715FVC-TR
Description
Industrial Optical Sensors Ambient Light Sensor Digital 16Bit Serial
Manufacturer
Rohm Semiconductor
Type
Ambient Light Sensor with Digital Outputr
Series
-r
Datasheets

Specifications of BH1715FVC-TR

Product
Ambient Light Sensor
Ic Function
Light To Digital Output Sensor
Supply Voltage Range
2.4V To 3.6V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
SOP
No. Of Pins
6
Supply Voltage Max
3.6V
Wavelength
560nm
Output Type
I²C™
Package / Case
6-WSOF Exposed Pad
Interface Type
Serial, I2C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BH1715FVC-TR
Manufacturer:
ROHM
Quantity:
3 385
Part Number:
BH1715FVC-TR
Manufacturer:
ROHM/罗姆
Quantity:
20 000
● Instruction Set Architecture
● Measurement mode explanation
Measurement time ( integration time ) of H-Resolution Mode is so long that some kind of noise( including in 50Hz / 60Hz noise ) is
rejected. And H-Resolution Mode is 1 l x resolution so that it is suitable for darkness ( less than 10 lx )
● Explanation of Asynchronous reset and Reset command "0000_0111"
1)
2)
We recommend to use H-Resolution Mode.
Continuously H-Resolution Mode
Continuously L-Resolution Mode
Asynchronous reset
All registers are reset. It is necessary on power supply sequence. Please refer "Timing chart for VCC and DVI power supply
sequence" in this page. It is power down mode during DVI = 'L'.
Reset command
Reset command is for only reset Illuminance data register. ( reset value is '0' ) It is not necessary even power supply
sequence. It is used for removing previous measurement result. This command is not working in power down mode, so that
please set the power on mode before input this command.
One Time H-Resolution Mode
One Time L-Resolution Mode
Change Measurement time
Change Measurement time
Power Down
Instruction
Power On
Measurement Mode
( High bit )
( Low bit )
H-Resolution Mode
L-Resolution Mode
Reset
011_MT[4,3,2,1,0]
01000_MT[7,6,5]
Measurement Time.
0000_0000
0000_0001
0001_0000
0010_0000
0001_0011
0010_0011
0000_0111
Opecode
Typ. 120ms.
Typ. 16ms.
5 / 15
No active state.
Waiting for measurement command.
Reset Data register value. Reset command is not acceptable in
Power Down mode.
Start measurement at 1lx resolution.
Measurement Time is typically 120ms.
Start measurement at 4lx resolution.
Measurement Time is typically 16ms.
Start measurement at 1lx resolution.
Measurement Time is typically 120ms.
It is automatically set to Power Down mode after measurement.
Start measurement at 4lx resolution.
Measurement Time is typically 16ms.
It is automatically set to Power Down mode after measurement.
Change measurement time.
※ Please refer "adjust measurement result for influence of optical
window."
Change measurement time.
※ Please refer "adjust measurement result for influence of optical
window."
Resolution
1 Lx.
4 Lx.
Comments
※ Don't input the other opecode.

Related parts for BH1715FVC-TR