LG T676-P1Q2-24-Z OSRAM Opto Semiconductors Inc, LG T676-P1Q2-24-Z Datasheet

Standard LED - SMD Green, 570nm 112mcd, 20mA

LG T676-P1Q2-24-Z

Manufacturer Part Number
LG T676-P1Q2-24-Z
Description
Standard LED - SMD Green, 570nm 112mcd, 20mA
Manufacturer
OSRAM Opto Semiconductors Inc
Type
Uni-Colorr
Datasheet

Specifications of LG T676-P1Q2-24-Z

Led Size
2.4 mm X 2.4 mm X 0.9 mm
Illumination Color
Green
Operating Voltage
2.4 V
Wavelength
570 nm
Luminous Intensity
112 mcd (Max)
Mounting Style
SMD/SMT
Operating Current
30 mA
Lens Shape
Circular
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Peak Wavelength
572 nm
Package / Case
PLCC-2
Viewing Angle
120 deg
Package Type
PLCC
Emitting Color
Yellow Green
Test Current (it)
20mA
Forward Current
30mA
Dominant Wave Length
570nm
Luminous Flux
0.24lm
Forward Voltage
2.4V
Product Length (mm)
3.4mm
Product Height (mm)
2mm
Product Depth (mm)
3mm
Mounting
Surface Mount
Shape Type
Circular
Chip Material
AlGaInP
Main Category
Chip LED
Number Of Elements
1
Pin Count
2
Operating Temperature Classification
Industrial
Lens Type
Colorless Non Diffused
Operating Temp Range
-40C to 100C
Reverse Voltage
12V
Power Dissipation
80mW
Lens Dimensions
2.4x2.4x0.9mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q65110A2178
Hyper TOPLED
Hyper-Bright LED
Lead (Pb) Free Product - RoHS Compliant
LG T676, LP T676
full production
Besondere Merkmale
• Gehäusetyp: weißes P-LCC-2-Gehäuse,
• Besonderheit des Bauteils: extrem breite
• Wellenlänge: 570 nm (grün),
• Abstrahlwinkel: Lambertscher Strahler (120°)
• Technologie: InGaAlP (grün, pure green)
• optischer Wirkungsgrad: 5 lm/W (grün),
• Gruppierungsparameter: Lichtstärke,
• Verarbeitungsmethode: für alle
• Lötmethode: IR Reflow Löten und
• Vorbehandlung: nach JEDEC Level 2
• Gurtung: 8-mm Gurt mit 2000/Rolle, ø180 mm
• ESD-Festigkeit: ESD-sicher bis 2 kV nach
• Erweiterte Korrosionsfestigkeit:
Anwendungen
• Informationsanzeigen im Innen- und
• optischer Indikator
• Hinterleuchtung (LCD, Handy, Schalter,
• Innenbeleuchtung im Automobilbereich
• Markierungsbeleuchtung (z.B. Stufen,
• Einkopplung in Lichtleiter
• Laufschriftanzeigen
• Signal- und Symbolleuchten
2009-12-14
farbloser klarer Verguss
Abstrahlcharakteristik; ideal für
Hinterleuchtungen und Einkopplungen in
Lichtleiter
560 nm (pure green)
1.5 lm/W (pure green)
Wellenlänge
SMT-Bestücktechniken geeignet
Wellenlöten (TTW)
oder 8000/Rolle, ø330 mm
JESD22-A114-D
Details siehe Seite 9
Außenbereich
Tasten, Displays, Werbebeleuchtung,
Allgemeinbeleuchtung)
(z. B. Instrumentenbeleuchtung)
Fluchtwege, u.ä.)
®
1
Features
• package: white P-LCC-2 package, colorless
• feature of the device: extremely wide viewing
• wavelength: 570 nm (green),
• viewing angle: Lambertian Emitter (120°)
• technology: InGaAlP (green, pure green)
• optical efficiency: 5 lm/W (green),
• grouping parameter: luminous intensity,
• assembly methods: suitable for all
• soldering methods: IR reflow soldering and
• preconditioning: acc. to JEDEC Level 2
• taping: 8 mm tape with 2000/reel, ø180 mm
• ESD-withstand voltage: up to 2 kV acc. to
• Superior Corrosion Robustness:
Applications
• indoor and outdoor displays
• optical indicators
• backlighting (LCD, cellular phones, switches,
• interior automotive lighting
• marker lights (e.g. steps, exit ways, etc.)
• coupling into light guides
• light writing displays
• signal and symbol luminaire
clear resin
angle; ideal for backlighting and coupling in light
guides
560 nm (pure green)
1.5 lm/W (pure green)
wavelength
SMT assembly methods
TTW soldering
or 8000/reel, ø330 mm
JESD22-A114-D
details see page 9
keys, displays, illuminated advertising, general
lighting)
(e.g. dashboard backlighting)

Related parts for LG T676-P1Q2-24-Z

LG T676-P1Q2-24-Z Summary of contents

Page 1

... Hyper TOPLED Hyper-Bright LED Lead (Pb) Free Product - RoHS Compliant LG T676, LP T676 full production Besondere Merkmale • Gehäusetyp: weißes P-LCC-2-Gehäuse, farbloser klarer Verguss • Besonderheit des Bauteils: extrem breite Abstrahlcharakteristik; ideal für Hinterleuchtungen und Einkopplungen in Lichtleiter • Wellenlänge: 570 nm (grün), 560 nm (pure green) • ...

Page 2

... The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LG T676-P1Q2-24 means that only one group P1, P2 will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. ...

Page 3

... A Wärmewiderstand Thermal resistance 4) Seite 15 Sperrschicht/Umgebung 4) page 15 Junction/ambient Sperrschicht/Lötpad Junction/soldering point 2009-12-14 Symbol Wert Symbol Value – 40 … + 100 op T – 40 … + 100 stg T + 125 200 tot R 500 280 T676, LP T676 Einheit Unit °C °C ° K/W K/W ...

Page 4

... F V (typ (max.) F (typ (max (typ.) peak peak TC (typ.) dom dom TC (typ η (typ.) opt 4 LG T676, LP T676 Werte Value LG LP 572 562 570* 560* –4/+5 ± 120 120 1.8 1.8 2.0 2.0 2.4 2.4 0.01 0. 0.12 0.10 λpeak 0.10 0.10 λ ...

Page 5

... Luminous Intensity I (mcd) V 11.2 ... 14.0 14.0 ... 18.0 18.0 ... 22.4 22.4 ... 28.0 28.0 ... 35.5 35.5 ... 45.0 45.0 ... 56.0 56.0 ... 71.0 71.0 ... 90.0 90.0 ... 112.0 112.0 ...140 T676, LP T676 green max. 569 572 575 2) Seite 15 Lichtstrom 1) page 15 Luminous Flux Φ (mlm (typ.) 50 (typ.) 60 (typ.) 75 (typ ...

Page 6

... Seite 15 2) page 15 pure-green 500 550 20˚ 10˚ 0˚ ϕ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ T676, LP T676 V λ green 600 650 20˚ 40˚ 60˚ 80˚ OHL00570 nm 700 λ OHL01660 100˚ 120˚ ...

Page 7

... Durchlassstrom 2) page 15 Forward Current ° 1.4 1.6 1.8 2.0 2009-12-14 Relative Lichtstärke Relative Luminous Intensity OHL00457 2 Relative Lichtstärke Relative Luminous Intensity T676, LP T676 2) 7) Seite page °C V(20 mA (20 mA pure green 5 green - Seite 15 2) page 15 I (25 °C ...

Page 8

... Zulässige Impulsbelastbarkeit Permissible Pulse Handling Capability Duty cycle D = parameter 2009-12-14 OHL01031 ˚C 100 Zulässige Impulsbelastbarkeit F p Permissible Pulse Handling Capability = 25 °C Duty cycle A OHL00316 0.005 0.01 0.02 0.05 0.1 0.2 0 T676, LP T676 D = parameter ° 0.005 0.01 0.02 -1 0.05 10 0.1 0.2 0 OHL01432 ...

Page 9

... Verpackungseinheit 2000/Rolle, ø180 mm oder 8000/Rolle, ø330 mm 8) page 15 Packing unit 2000/reel, ø180 mm or 8000/reel, ø330 mm 4 (0.157) 2 (0.079) 2.9 (0.114) 4 (0.157 T676, LP T676 2.1 (0.083) 1.7 (0.067) 0.9 (0.035) 0.7 (0.028 0.6 (0.024) 0.4 (0.016) GPLY6724 Cathode/Collector Marking OHAY2271 ...

Page 10

... Power TOPLED 3.3 (0.130) Anode 0.8 (0.031) 0.7 (0.028) Fläche darf elektrisch nicht beschaltet werden. Do not use this area for electrical contact. Lötstoplack Solder resist 10 LG T676, LP T676 IR-Reflow Löten IR Reflow Soldering 2.6 (0.102) 2 Cu-Fläche > Cu-area > OHLPY970 ® ® ...

Page 11

... Welle 1. wave ca 200 K/s 5 K/s C Zwangskühlung 2 K/s forced cooling 50 100 11 LG T676, LP T676 Vorbehandlung nach JEDEC Level 2 Preconditioning acc. to JEDEC Level 2 (nach J-STD-020B) (acc. to J-STD-020B) 260 ˚C 245 ˚C 235 ˚ min 30 s max Ramp Down 6 K/s (max) 100 s max ...

Page 12

... N W min 1 8 (0.331 + 0.079) 60 (2.362) 8 (0.331 + 0.079) 60 (2.362 T676, LP T676 Bin1: Bin Information Color 1 Lx xxxx Bin2: Product Name Bin3: RoHS Compliant ML Temp ST 2 260 C RT Additional TEXT R077 DEMY ...

Page 13

... WET units bake 15% necessary if units, examine wet, If units bake 10% necessary if units, wet, examine If dry. adequately desiccant still change parts 5% wet, If MIL-I-8835 Indicator Humidity Desiccant Barcode label 13 LG T676, LP T676 Humidity indicator Barcode label OHA00539 Barcode label Packing Sealing label OHA02044 ...

Page 14

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 10) page 15 components may only be used in life-support devices or systems OSRAM OS. 2009-12-14 11) page 15 with the express written approval T676, LP T676 Date of change 2006-10-16 2009-12-14 ...

Page 15

... Systemen lebenserhaltenden 11 T676, LP T676 Brightness groups are tested at a current pulse duration and a tolerance of ± 11%. Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do correspond to the actual parameters of each single ...

Related keywords