AFBR-57R6AEZ Avago Technologies US Inc., AFBR-57R6AEZ Datasheet - Page 12

Fiber Optic Transmitters, Receivers, Transceivers Transceiver

AFBR-57R6AEZ

Manufacturer Part Number
AFBR-57R6AEZ
Description
Fiber Optic Transmitters, Receivers, Transceivers Transceiver
Manufacturer
Avago Technologies US Inc.
Series
-r
Datasheet

Specifications of AFBR-57R6AEZ

Product
Transceiver
Data Rate
4.25 GBd, 2.125 GBd, 1.0625 GBd, 1.25 GBd
Wavelength
860 nm (Max)
Maximum Rise Time
0.09 ns/0.15 ns
Maximum Fall Time
0.09 ns/0.15 ns
Pulse Width Distortion
0.06 ns (Max)/0.062 ns (Max)
Maximum Output Current
300 mA
Operating Supply Voltage
2.97 V to 3.63 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 10 C
Package / Case
SFP
Mounting Type
SFP
Voltage - Supply
2.97 V ~ 3.63 V
Connector Type
LC Duplex
Applications
Ethernet
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Multimode Fiber
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AFBR-57R6AEZ
Manufacturer:
Avago Technologies
Quantity:
135
12
Table 9. Transceiver SOFT DIAGNOSTIC Timing Characteristics
(T
Parameter
Hardware TX_DISABLE Assert Time
Hardware TX_DISABLE Negate Time
Time to initialize, including reset of TX_FAULT
Hardware TX_FAULT Assert Time
Hardware TX_DISABLE to Reset
Hardware RX_LOS Deassert Time
Hardware RX_LOS Assert Time
Hardware RATE_SELECT Assert Time
Hardware RATE_SELECT Deassert Time
Software TX_DISABLE Assert Time
Software TX_DISABLE Negate Time
Software Tx_FAULT Assert Time
Software Rx_LOS Assert Time
Software Rx_LOS Deassert Time
Analog parameter data ready
Serial bus hardware ready
Write Cycle Time
Serial ID Clock Rate
Notes:
10. Time from two-wire interface de-assertion of TX_DISABLE (A2h, byte 110, bit 6) to when the modulated optical output rises above 90% of
11. Time from fault to two-wire interface TX_FAULT (A2h, byte 110, bit 2) asserted.
12. Time for two-wire interface assertion of Rx_LOS (A2h, byte 110, bit 1) from loss of optical signal.
13. Time for two-wire interface de-assertion of Rx_LOS (A2h, byte 110, bit 1) from presence of valid optical signal.
14. From power on to data ready bit asserted (A2h, byte 110, bit 0). Data ready indicates analog monitoring circuitry is functional.
15. Time from power on until module is ready for data transmission over the serial bus (reads or writes over A0h and A2h).
16. Time from stop bit to completion of a 1-8 byte write command.
1. Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal.
2. Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal.
3. Time from power on or falling edge of Tx_Disable to when the modulated optical output rises above 90% of nominal.
4. From power on or negation of TX_FAULT using TX_DISABLE.
5. Time TX_DISABLE must be held high to reset the laser fault shutdown circuitry.
6. Time from loss of optical signal to Rx_LOS Assertion.
7. Time from valid optical signal to Rx_LOS De-Assertion.
8. Time from rising or falling edge of Rate_Select input until transceiver is in conformance with appropriate specification.
9. Time from two-wire interface assertion of TX_DISABLE (A2h, byte 110, bit 6) to when the optical output falls below 10% of nominal. Measured
C
from falling clock edge after stop bit of write transaction.
nominal.
= -10°C to 85°C, VccT, VccR = 3.3 V ± 10%)
t_rate_high
t_rate_low
Symbol
t_off
t_on
t_init
t_fault
t_reset
t_loss_on
t_loss_off
t_off_soft
t_on_soft
t_fault_soft
t_loss_on_soft
t_loss_off_soft
t_data
t_serial
t_write
f_serial_clock
Minimum
10
Maximum
10
1
300
100
100
100
10
10
100
100
100
100
100
300
10
400
1000
Unit
μs
ms
ms
μs
μs
μs
μs
ms
ms
ms
ms
ms
ms
ms
ms
ms
ms
kHz
Notes
Note 1
Note 2
Note 3
Note 4
Note 5
Note 6
Note 7
Note 8
Note 8
Note 9
Note 10
Note 11
Note 12
Note 13
Note 14
Note 15
Note 16

Related parts for AFBR-57R6AEZ