Datasheets

Specifications of SBL2E-100IR

Size
2.00" L x 1.20" W (50.8mm x 30.8mm)
Number Of I/os
10
Data Rate
115.2 Kbps
Interface Type
I2C, UART
Operating Voltage
3.3 V
Operating Current
300 mA
Operating Temperature Range
- 40 C to + 85 C
Board Size
1.2 in x 2 in
Data Bus Width
12 bit
Product
Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
For Use With/related Products
-
Lead Free Status / Rohs Status
 Details
Other names
Q5819275A
8.6 AT Command Examples
The following examples display the full transcript of serial communication including commands
sent and replies from the SBL2e. Commands are marked in
8.6.1 Changing the System IP Address
This example first queries the current IP address, and then changes the current IP to 10.1.1.79. Once
the IP address change request is made, the settings are saved, and the device reboots.
8.6.2 Configuring the Serial Server Listen Port
This example first queries the current TCP Serial Server listening port number, and then changes
the current port number to 30. Once the port number change request is made, the settings are saved.
No system restart was required.
8.6.3 Configure Outgoing Network Client Connection
This example changes the client connection‟s IP and port. Once the changes are made, the settings
are saved. No system restart was required.
SBL2e Dual Serial-to-Ethernet User's Manual
+++
OK>AT#CURIP?10.1.1.99
OK>AT#SYSIP=10.1.1.79
OK>AT&PIP Address Changed Rebooting
Waiting 2sec(s) to start 'A' to abort
+++
OK>AT#SER0SP?23
OK>AT#SER0SP=30
OK>AT&P2,Returning to listening connection
+++
OK>AT#SER0CI=10.1.1.78
OK>AT#SER0CP=30
OK>AT&P2,Returning to listening connection
red,
responses are marked in
Page 25
blue.

Related parts for SBL2E-100IR