6000-210023 Storm Interface, 6000-210023 Datasheet - Page 8

KEYPAD MATRIX OUTPUT 6000 SERIES

6000-210023

Manufacturer Part Number
6000-210023
Description
KEYPAD MATRIX OUTPUT 6000 SERIES
Manufacturer
Storm Interface
Series
6000r
Datasheets

Specifications of 6000-210023

Switch Type
Conductive Rubber
Number Of Keys
16
Matrix (columns X Rows)
4 x 4
Output Type
Matrix
Key Type
Polymer
Legend
Calculator Format
Interchangeable Legends
No
Illumination
Non-Illuminated
Seal Rating
IP65
Vandal Resistant (20j Bs En 60068-2-75
1997)
Overall Dimensions
124.0 mm × 118.5 mm × 17.5 mm
Front Plate
Brushed Stainless Steel
Keys
Super High Impact Polymer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
6000-210021
6000-210022
6000-210023
MGR1620
Section 4. Connectors and Connections - PS2/USB Output
The 6000 Series encoded keypad is supplied without a cable so that the user can select the correct cable length and
connector type to suit their application. Cables are offered as separately purchased options, or alternatively the user
can source their own cable to suit the application. The pinout details for the connectors are shown on the following
page.
Option 1 PS2 Minidin connector, straight cable, 2.5 metres long
Option 2 USB connector, straight cable, 2.5 metres long
Fitting Cables
WARNING : THE FOLLOWING MUST BE DONE IN AN ESSD SAFE HANDLING AREA
In order to fit the cable, the pod cover on the back of the keypad must be removed. Plug the molex connector into the
connector designated JP1 on the encoder pcb. Connect the earth tag to the securing nut and tighten. Set the positions
of the USB / PS2 selector switches (see table below). Note that SW2 toggles the function key output codes between
USA layout and UK layout. Ensure the grommet is correctly located into the slot in the pod; this provides strain relief
and sealing. Close the pod cover.
This document is provided for use and guidance of engineering personnel engaged in the installation or application of STORM data entry products manufactured by Keymat Technology Ltd.
Please be advised that all information, data, and illustrations contained within this document remain the exclusive property of Keymat Technology Ltd. and are provided for the express and
exclusive use as described above. This document is not supported by Keymat Technology’s engineering change note, revision or reissue system. Data contained within this document is subject
to periodic revision, reissue or withdrawal. Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not
responsible for any errors or omissions contained within this document.
SWITCH SETTINGS
OFF
ON
SW1
USB
PS/2
6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page 8 of 16
Application / Engineering Manual
FUNCTION KEYS USA
FUNCTION KEYS UK
6000 Series keypad for public environments
SW2
SW3
USB
PS/2

Related parts for 6000-210023