A16-CTM Omron, A16-CTM Datasheet - Page 132

CASE ROUND 16 SERIES MOMENTARY

A16-CTM

Manufacturer Part Number
A16-CTM
Description
CASE ROUND 16 SERIES MOMENTARY
Manufacturer
Omron
Type
Round Caser
Series
A16r
Datasheets

Specifications of A16-CTM

Switch Type
Push Button Switch
Operating Temp Range
-10C to 55C
Illumination
Not Illuminated
Mounting Style
Snap On
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
A16 Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
A16CTM
Precautions
Refer to the Technical Information for Pushbutton Switches (Cat. No. A143) and the Precautions section for the A16.
Mounting
When mounting the Case onto the Socket Unit, ensure that the orien-
tation is correct. Perform mounting with the • mark on the Case and
the TOP mark on the Socket Unit facing in the same direction.
130
Cat. No. A127-E1-03
Correct Use
Case
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
mark
In the interest of product improvement, specifications are subject to change without notice.
Socket Unit
TOP mark
Wiring
When using stranded wire, gather the ends of the strands together
before wiring.
When wiring, insert the wire until it comes into contact with some-
thing. After wiring is completed, pull on the wires to confirm that they
are connected securely.
After wiring, ensure that continuous pressure is not applied to the ter-
minals.
Refer to internal connections diagrams and confirm the terminal
numbers before performing wiring.
Screw-Less Clamps
Mounting Procedure
1. Strip a length of 10 mm off the end of the wire (allowable range:
2. Bunch wire strands together and straighten them.
3. Insert the wire into the insertion hole while pressing the release
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
Removing Procedure
Remove wires by pulling them while pressing the release button.
Note: When reusing wires that have already been locked, cut off the
10 1 mm).
button at the side of the hole. (Using a precision screwdriver is
recommended.)
locked.
end of the wire and strip the wire again before using.