PSE541-R04 SMC Corporation of America, PSE541-R04 Datasheet - Page 5

no-image

PSE541-R04

Manufacturer Part Number
PSE541-R04
Description
SENSOR VACUUM 101KPA 4MM REDUC
Manufacturer
SMC Corporation of America
Series
PSE540r
Datasheet

Specifications of PSE541-R04

Pressure Type
Vacuum
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Female, 0.8" (20.32mm) NPT
Output
Digital
Accuracy
±2%
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Operating Temperature
0°C ~ 50°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1021
{ Pressure Sensor
1. Do not drop, bump, or apply excessive impact
3. Do not use pressure sensors with corrosive and/or
4. Connection of sensor connector
1. The pressure sensors are CE marked; however, they
2. The pressure sensors do not have an explosion
2. The tensile strength of the cord is 50 N. Applying a
(PSE540: 980 m/s
dling. Although the body of the sensor may not be
damaged, the inside of the sensor could be damaged
and lead to malfunction.
greater pulling force to it can cause malfunction.
When handling, hold the body of the sensor—do not
dangle it from the cord.
flammable gases or liquids.
• Cut the sensor cable as illustrated to the right.
• Referring to the table below, insert each
• Confirm that the numbers on the
• Press in the central part of Part A vertically with
• A sensor connector cannot
• For connection to SMC Series PSE300 pressure switches, use
• For detailed information about e-con connectors, please
are not equipped with surge protection against
lightning. Lightning surge countermeasures should
be applied directly to system components as
necessary.
proof rating. Never use pressure sensors in the
presence of flammable or explosive gases.
Connector
lead wire of the cable at the position
marked with a number corresponding to
connector match the colors of the
wires and that the wires are inserted to the
bottom. Press Part A by hand for
temporary fixing.
a tool such as pliers.
be taken apart for reuse
once it is crimped. If the wire
arrangement is incorrect or
if the wire insertion fails, use a new sensor connector.
sensor connectors (ZS-28-C) or e-con connectors listed below.
consult the manufacturers of the respective connectors.
Warning
Warning
no.
1
2
3
4
Sumitomo 3M
Tyco Electronics AMP
For PSE200 (ZS-26-E)
Manufacturer
Black (OUT: 1 to 5 V)
Operating Environment
Series
Specific Product Precautions 1
Be sure to read before handling.
Brown (DC (+))
Not connected
Blue (DC (-))
2
, PSE560: 500 m/s
Handling
Wire core color
PSE
the color of the lead wire.
For PSE300 (ZS-28-C)
Sheath
Black (OUT: 1 to 5 V)
37104-3101-000FL
Brown (DC (+))
Not connected
Blue (DC (-))
1-1473562-4
Part no.
2
) while han-
20 mm or more
Insulator
Part-A
1. Use of toxic, corrosive or flammable gases
2. Fluid compatibility
Helium leakage test
Helium leakage test is conducted on the welded parts. Use ferrules
by Crawford Fittings (Swagelok
glands by Cajon (VCR
glands of other brands are to be used, be sure to conduct helium
leakage test before using those products.
{ Controller
1. Incorrect wiring can damage the switch and cause
2. Do not attempt to insert or pull out the pressure
1. Do not drop, bump, or apply excessive impact
2. The tensile strength of the power supply/output
3. Wire separately from power lines and high voltage
4. If a commercial switching regulator is used, make
Since the switch uses stainless steel 316L as the material of the
pressure sensor and fittings, do not use toxic or corrosive
gases.
Since the switch uses stainless steel 316L as the wetted
material (for the pressure sensor and fittings), use fluids that will
not corrode this material.
(For the corrosiveness of the fluids, please consult with the
malfunction or erroneous switch output. Connections
should be done while the power is turned off.
sensor or its connector when the power is on. Switch
output may malfunction.
lines, avoiding wiring in the same conduit with these
lines. Malfunctions may occur due to noise from these
other lines.
sure that the F.G. terminal is grounded.
(100 m/s
controller case may not be damaged, the inside of
the controller could be damaged and cause
malfunction.
connection cable is 50 N; that of the pressure sensor
lead wire with connector is 25 N. Applying a greater
pulling force than the applicable specified tensile
strength to either of these components can lead to
malfunction. When handling, hold the body of the
controller—do not dangle it from the cord.
manufacturers of the respective fluids.)
Warning
Warning
Warning
2
) while handling. Although the body of the
®
fittings) as URJ fittings. If ferrules, seals, or
Connection
Air Supply
Handling
®
fittings) as TSJ fittings, seals and
16-3-29
ZSE„
ISE„
PSE
Z
PS
Z
ZSP
ISA2
IS„
ZSM
PF2„
IF„
Data
I
I
SE3
SE
1
2

Related parts for PSE541-R04