MP3V5010GP Freescale Semiconductor, MP3V5010GP Datasheet - Page 6

IC PRESSURE SENSOR 8-SOP

MP3V5010GP

Manufacturer Part Number
MP3V5010GP
Description
IC PRESSURE SENSOR 8-SOP
Manufacturer
Freescale Semiconductor
Type
Gager
Datasheet

Specifications of MP3V5010GP

Pressure Type
Gauge
Operating Pressure
1.45 PSI
Port Size
Male, 0.12" (3mm) OD
Output
0.1 ~ 3.1 V
Voltage - Supply
2.7 V ~ 3.3 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
8-SOP Side Port
Output Voltage Range
0.1 to 3.1V
Pressure Range
0 to 10KPa
Overload Pressure (max)
75KPa
Mounting
Surface Mount
Pin Count
8
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Package Type
Case 1369-01
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.3V
Accuracy
5 %
Output Type
Analog
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Voltage (min)
2.7 VDC
Supply Voltage (max)
3.3 VDC
Supply Current
7 mA
Operating Pressure Range
0 To 10kPa
Connection Size
0.125"
Sensitivity, V/p
270mV/kPa
Sensor Case Style
SOP
No. Of Pins
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MP3V5010
6
PRESSURE (P1)/VACUUM (P2) SIDE IDENTIFICATION TABLE
as the Pressure (P1) side and the Vacuum (P2) side. The
Pressure (P1) side is the side containing fluoro silicone gel
which protects the die from harsh media. The pressure
MINIMUM RECOMMENDED FOOTPRINT FOR SURFACE MOUNTED APPLICATIONS
design. The footprint for the surface mount packages must be
the correct size to ensure proper solder connection interface
between the board and the package. With the correct
MP3V5010GC6U/C6T1
MP3V5010GP
MP3V5010DP
MP3V5010GVP
Freescale designates the two sides of the pressure sensor
Surface mount board layout is a critical portion of the total
Pressure
Pressure
Pressure Error Band
Error
(kPa)
–0.1
–0.2
–0.3
–0.4
–0.5
0.5
0.4
0.3
0.2
0.1
0
Part Number
0
0.060 TYP 8X
1.52
Figure 5. Small Outline Package Footprint
0.100 TYP 8X
2.54
Case Type
0.660
16.76
482A
1369
1351
1368
sensor is designed to operate with positive differential
pressure applied, P1 > P2.
following table:
footprint, the packages will self align when subjected to a
solder reflow process. It is always recommended to design
boards with a solder mask layer to avoid bridging and
shorting between solder pads.
The Pressure (P1) side may be identified by using the
inch
mm
Side with Port Attached
Side with Part Marking
Side with Part Marking
Side with Port Attached
SCALE 2:1
0.100 TYP 8X
2.54
0.300
7.62
0 to 10 (kPa)
Pressure
10
Side Identifier
Pressure (P1)
Freescale Semiconductor
Pressure (kPa)
Error (Max)
±0.5 (kPa)
Sensors

Related parts for MP3V5010GP