E8MS-N0 Omron, E8MS-N0 Datasheet
E8MS-N0
Specifications of E8MS-N0
Related parts for E8MS-N0
E8MS-N0 Summary of contents
Page 1
... MPa 0 to −101 kPa −101 to 101 kPa MPa 0 to −101 kPa Output configuration Number of sensor inputs NPN open collector CSM_E8MS_E8M_DS_E_3_1 Output configuration Model E8MS-01 E8MS-10 Linear output E8MS-N0 E8MS-N1 * Output configuration Model E8M-A1-S Linear output E8M-10 E8M-N0 Models 4 K3C-MP8 * CH 1 ...
Page 2
... Appearance Model Y92A-40-S Sensor and Controller Combinations Use the Pressure Controllers in the following combinations. The E89-M3/M4 is required when using the Sensor as a single unit. Model E89-M3-S E8MS-01 No E8MS-10 No E8MS-N0 No E8MS- E8M-A1-S No E8M-10 Yes E8M-N0 Yes * Connect the E8MS- E89-M4-S Sensor I/O Connector. Do not connect Controller. A Controller is not necessary. ...
Page 3
... R (PT) 1/8 taper screw and M5 female screw Connection method Connector Weight (packed state) Approx Material Pressure port Aluminum Accessories Instruction manual E8MS- −101 kPa MPa 1.5 MPa 400 kPa times each for 8 min and Z directions 2 3 times each and Z directions E8MS/E8M E8MS-N0 E8MS-N1 −101 to 100 kPa 3 ...
Page 4
... MPa * ±5% FS max. ±0.12% FS/°C max times each and Z directions R (PT) 1/8 and M5 female screw Connector Approx Stainless steel (SUS304) Aluminum, polyether sulfonic resin Instruction manual E8MS/E8M E8M- −101 kPa 400 kPa times each for 8 min and Z directions M5 male screw Approx ...
Page 5
... Accessories Instruction manual, Adapter, Water-proof Packing * Pressure differentials are displayed with a minus (−) sign. E8M-MP8 E8MS-10 E8MS-01 E8M- 100 kPa MPa times each for 8 min and Z directions (with 2 3 times each and Z directions (with power supplied) E8MS/E8M E8MS-N0 E8M- −101 kPa) 5 ...
Page 6
... Pressure (kPa) E8M-A1 200 400 600 800 1,000 0 Differential pressure (Pa) between positive and negative ports E8MS-10/E8M- 200 400 600 800 1,000 0 Pressure (kPa) E8MS- −101 −60 − 101 Pressure (kPa) E8MS/E8M E8MS-N0/E8M- −20 −40 −60 −80 −101 0 Pressure (kPa) 6 ...
Page 7
... Pressure (kPa) E8MS- −1 −2 −3 −4 −5 −101 −60 − 101 Pressure (kPa) E8MS/E8M E8MS-N0/E8M-N0 5 E8MS-N0 4 E8M- −1 −2 −3 −4 −5 −20 −40 −60 −80 −101 0 Pressure (kPa) 7 ...
Page 8
... E8M-10 0.5 0.4 0.3 0.2 Pressure 0 0.1 0 −0.1 Rated pressure −0.2 −0.3 −0.4 −0.5 10.5 11 11.5 12 12.5 13 13.5 Voltage (V) E8MS/E8M E8MS-N0 0.5 0.4 0.3 0.2 Pressure 0 0.1 0 −0.1 Rated pressure −0.2 −0.3 −0.4 −0.5 10.5 11 11.5 12 12.5 13 13.5 Voltage (V) E8M-N0 0.5 ...
Page 9
... Rated pressure −3 −4 −5 − Temperature (˚C) E8M- Pressure −1 −2 Rated pressure −3 −4 −5 − Temperature (˚C) E8MS/E8M E8MS- Pressure −1 −2 Rated pressure −3 −4 −5 − Temperature (˚C) E8M- Pressure −1 Rated pressure −2 −3 −4 − ...
Page 10
... I/O Circuit Diagrams Sensor Output configuration Model E8MS-01 E8MS-10 E8MS-N0 E8MS- E8M-A1-S linear output E8M-10 E8M-N0 Controller Output configuration Model NPN output E8M-MP8 Output circuit Connector Brown 3 +V Pressure Sensor main 2 Black (linear output) circuit Load Blue Brown +V Power indicator Pink * ...
Page 11
... Protective Front Cover . . . . . . . . . . . . . . . . . . . . . . . Y92A-40 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y92F-48-S (This Adapter is to mount the E8M-MP8 in the panel cutout dimensions for the K3C Series.) Water-proof Packing (Accessory) Protective Front Cover Adapter SET Button Panel Mounting Adapter (Accessory) E8MS/E8M Unit indicator (orange) Channel display (red) Down Button 11 ...
Page 12
... Precautions for Correct Use Do not use this product in atmospheres or environments that exceed product ratings. ● Installation Connecting and Locking the E8MS Sensor I/O Connector (E89-M4) (1)Hold both ends of the female connector connected to the Sensor I/O Connector so that the protrusion on the female connector faces ...
Page 13
... Sensor under the rated pressure. (5)Do not insert any wire into the pressure port. Doing so may damage the pressure elements and cause a malfunction. (6)Do not apply any tensile strength in excess of 20N for E8MS, 30N Flat-blade screwdriver for E8M to the cables or connectors. ...
Page 14
... Dimensions Main Unit Sensors E8MS-01 E8MS-10 M5 (depth: 7.5 mm) E8MS-N0 E8MS-N1 (15) E8M-A1-S 19 Note: One XN2A-1430 is supplied together with the E8M-A1-S. E8M-10 M8 hexagonal nut R1 Pressure port 13.5 16.7 (37.5) E8M-N0 M4 hexagonal nut M5 7 Pressure port 16.7 7 (31) Connector: DF13B-3P-1.25V (21) R (PT)1/8 by Hirose Electric Pressure port (8 ...
Page 15
... Controller E8M-MP8 (43.9) ------------------------------------------- ------------------------------------------- ------------------------------------------- ------------------------------------------- Accessories (Order Separately) Sensor I/O Connector For the E8M Only E89-M3-S Note: One XN2A-1430 is provided. with the E89-M3-S. For the E8MS Only E89-M4-S 8.9 Note: One XN2A-1430 is provided with the E89-M4-S. 53 (43.5) 47 40.1 (9.4) ( (42x42) (42.4x42.4) (46.4) Panel Mounting Adapter ...
Page 16
... Note: One Connector is provided with the E89-M3-S or E89-M4-S. Hard Protective Front Cover Y92A-40-S (17.8) 15 Display surface 3.5 48x48 2 37x37 E8MS/E8M 6 2 (pitch) 1 3.4 3.3 13.55 5.05 12.2 17.6 7.5 (strip gauge) 6 15.8 1.2 dia. (internal) 1.65 dia. (external) 1 ...
Page 17
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...