UGW3S8XESM33 Unigen Corp, UGW3S8XESM33 Datasheet - Page 15

MODULE PAN-SMT-800 MOBO

UGW3S8XESM33

Manufacturer Part Number
UGW3S8XESM33
Description
MODULE PAN-SMT-800 MOBO
Manufacturer
Unigen Corp
Datasheet

Specifications of UGW3S8XESM33

Frequency
868MHz ~ 870MHz
Data Rate - Maximum
152.3kbps
Modulation Or Protocol
FSK
Power - Output
15dBm
Sensitivity
-111dBm
Voltage - Supply
2.4 V ~ 3.6 V
Current - Receiving
14mA
Current - Transmitting
62mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Other names
784-1028-2
Solutions for a Real Time World
registers. In a typical application, the XE1203F is programmed by a microcontroller via the 3-wire
serial bus SI, SO, SCK to write to and read from these registers.
The Receiver converts the incoming 2-level FSK modulated signal into a synchronized bit stream.
The Transmitter performs the modulation of the carrier by an input bit stream and the
transmission of the modulated signal.
The Frequency Synthesizer generates the local oscillator (LO) signal for the receiver section as
well as the continuous phase FSK modulated signal for the transmitter section.
The Service Blocks provide the internal voltage and current sources and provide all the necessary
functions for the circuit to work properly.
The Configuration Registers are a set of variable-length registers that are used to store various
settings to operate the XE1203F transceiver circuit. They are listed below in the table below.
These registers are accessed in write or read mode through the 3-wire serial bus.
Re-Tek - 1533
94539
support@unigen.com
http://www.unigen.com
ConfigSwitch
RTParam
FSParam
SWParam
DataOut
ADParam
Pattern
Name
1-bit data to switch between 2 sets of user-predefined
SWParam Configuration Registers
Receiver and transmitter parameters
LO, Bitrate, Deviation and other frequency parameters
2 sets of user-predefined configuration registers
Status register which can be read through the 3-wire
serial interface
Additional parameters
Reference pattern for the “pattern recognition” feature
PAN 433/868/902 MHz - UGW3S
Copyright Unigen Corporation, 2008
Control Registers
- 15 -