XBP24-ACI-001 Digi International/Maxstream, XBP24-ACI-001 Datasheet - Page 60

no-image

XBP24-ACI-001

Manufacturer Part Number
XBP24-ACI-001
Description
MODULE 802.15.4 100MW CHIP ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-ACI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no AT Command Response will be given.
Set to match the 64-bit address
of the destination, MSB first,
LSB last. Broadcast =
0x000000000000FFFF. This field is ignored if the 16-bit
network address field equals anything other than
0xFFFE.
Frame ID (Byte 5)
Start Delimiter
0x7E
64-bit Destination Address
Identifies the UART data frame being reported.
Note: If Frame ID = 0 in AT Command Mode,
no AT Command Response will be given.
Identifies the UART data frame being reported .
Note: If Frame ID = 0 in AT Command Mode,
no AT Command Response will be given.
(bytes 6-13)
MSB
AT Command Response
Remote AT Command Request
Length
Start Delimiter
API Identifier Value: 0x88
Response to previous command.
In response to an AT Command message, the module will send an AT Command Response mes-
sage. Some commands will send back multiple frames (for example, the ND (Node Discover) and
AS (Active Scan) commands). These commands will end by sending a frame with a status of
ATCMD_OK and no cmdData.
Figure 3‐09. AT Command Response Frames.
Figure 3‐10. AT Command Response Frames.
API Identifier Value: 0x17
Allows for module parameter registers on a remote device to be queried or set
Figure 3‐11. Remote AT Command Request
0x7E
LSB
Frame ID (Byte 5 )
© 2009 Digi Internatonal, Inc.
API Identifier
Start Delimiter
0x17
0x7E
Frame ID (Byte 5 )
API-specific Structure
MSB
Frame Data
Length
MSB
Identifier-specific Data
LSB
API Identifier
Length
cmdData
0x88
LSB
API-specific Structure
API Identifier
Set to match the 16-bit network
address of the destination, MSB
first, LSB last. Set to 0xFFFE if 64-bit
addressing is being used.
0x88
Command Name - Two
ASCII characters that
identify the AT Command.
Frame Data
AT Command (Bytes 6-7)
Checksum
1 Byte
API-specific Structure
Identifier-specific Data
16-bit Destination Network Address
cmdData
Command Name - Two
ASCII characters that
identify the AT Command .
Frame Data
Command Options (byte 16)
AT Command (Bytes 6-7)
Identifier-specific Data
(bytes 14-15)
cmdData
Checksum
1 Byte
0x02 - Apply changes on remote. (If
not set, AC command must be sent
before changes will take effect.)
All other bits must be set to 0.
Checksum
Status (Byte 8)
0 = OK
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
1 Byte
Command Name (bytes
Status (Byte 8)
0 = OK
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
Name of the
command
17-18)
The HEX (non-ASCII) value
of the requested register
Value (Byte(s) 9-n)
If present, indicates the requested
parameter value to set the given
register. If no characters present,
the register is queried.
The HEX (non -ASCII) value
of the requested register
Command Data (byte 19-n)
Value (Byte(s) 9-n)
     60