MODULE AC SWITCH RECEIVER 433MHZ

FCTN-WALL-433

Manufacturer Part Number
FCTN-WALL-433
Description
MODULE AC SWITCH RECEIVER 433MHZ
Manufacturer
Linx Technologies Inc
Datasheet

Specifications of FCTN-WALL-433

Function
Receiver, Relay
Modulation Or Protocol
ASK, OOK
Frequency
433MHz
Applications
General Remote Control, Wire Elimination
Interface
Receiver, Latched Output
Sensitivity
-95dBm
Data Rate - Maximum
1.2 kbps
Features
Switch 1,800W (15 Amps) or 1HP @ 120 VAC
Voltage - Supply
100 V ~ 120 VAC
Package / Case
Module
Board Size
104.1 mm x 56.6 mm x 64.3 mm
Minimum Operating Temperature
- 30 C
Product
RF Modules
Maximum Frequency
433.92 MHz
Supply Voltage (max)
110 V
Maximum Operating Temperature
+ 70 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
FCTN-WALL-433-1
FCTN-WALL-433-1
SAFETY AND COMPLIANCE
UNDERWRITERS LABORATORIES (UL)
Page 6
The AC Function Module has been designed and tested to meet certain safety
and compliance standards. Please read, understand, and follow all safety and
compliance messages within this guide and check to ensure that the standards
to which the product has been tested are appropriate for your intended use.
The AC Function Module has been tested by Underwriters Laboratories (UL
compliance with the following standards:
The AC Function Module is UL
appliance control. Operation in environments or applications other than those
associated with the above is not recommended.
The use of the UL
licensee. Linx offers a full customization program for our valued OEM partners
that is designed to maintain compliance with use of the UL
may not be placed on labels or graphics for this product not originating from Linx.
End user manuals for the AC Function Module should indicate that no user
serviceable parts are contained inside the unit. The end user manual should not
contain replacement fuse information or other internal diagrams. A service
manual, however, may contain complete fuse information, and should be
accompanied by the following statement:
WARNING: To reduce the risk of electrical shock, replace only with the
same type and rating of fuse.
A service manual may reference the following approved replacement fuses only:
Littelfuse p/n 326025, 25A, 125V, slow blow
Schurter p/n 7043.8230, 20A, 250V, time lag
Cooper Bussman p/n MDA-20-R, 20A, 250VAC, time delay
Littelfuse p/n 314025, 25A, 250 V, Fast Acting
UL 244A
®
mark is protected, and may be used only by the original
UL 916
®
listed for indoor operation only as a solid-state
CSA C22.2 #24-93
®
mark. The UL
®
®
mark
) for
COMPLIANCE REQUIREMENTS
Place the above statement in the instruction manual or insert card.
LABELING REQUIREMENTS
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with FCC regulations, shielded cables must be used
with this equipment. Operation with non-approved equipment or unshielded cables
is likely to result in interference to radio and TV reception. The user is cautioned that
changes and modifications made to the equipment without the approval of
manufacturer could void the user’s authority to operate this equipment.
The AC Function Module has been tested by an FCC-approved facility and been
found to comply with all applicable FCC and Industry Canada requirements as of
the date of this document. A Declaration of Conformity (DoC) is on file. It is the
user’s responsibility to determine if any additional regulatory or safety testing will
be required on the user’s completed product. In products where no additional
testing is required, no further labeling of the unit is needed unless the module will
be placed inside another housing. It is, however, necessary to include the
following statement in the end product’s instruction manual or insert card.
In cases where the FCTN-WALL-*** module is incorporated inside a product and
its standard labeling is not visible, the end product must be labeled as shown.
The label shall not be a stick-on paper label. The label shall be “permanently affixed” to the device
(meaning the label is etched, engraved, stamped, silk-screened, indelibly printed on a permanently
attached part of the device, or on a nameplate fastened to the equipment by welding, riveting, or a
permanent adhesive). The label must be designed to last the expected lifetime of the equipment in
the environment in which the equipment may be operated and may not be readily detachable.
When the device is constructed in two or more sections connected by wires and marketed together,
the label is required to be affixed only to the main control unit.